Product Specifications - ADTRAN 17600072F1S Quick Start Manual

Service delivery gateway

Advertisement

Adtran
Quick Setup for the SDG-8622
For devices with SmartOS installed, scan the QR code labeled WiFi QuickStart located on the back of the unit. You will be
presented with a series of self-guided steps to choose your account password, select gateway or access point mode,
and configure the Wi-Fi SSID and passphrase. The specified account password will be used when initially logging into
the GUI on the SDG.
Logging Into the SDG-8622
Using SmartOS
A browser-based user interface (GUI) is used to manually configure the SDG-8622. The following steps describe how to
connect and login to the device:
 1. Ensure your computer is connected to the SDG-8622 either via Wi-Fi or Ethernet connection to one of the LAN ports.
 2. Configure your computer's network interface to acquire an IP address automatically using DHCP.
 3. Open a web browser and enter the following: http://router or http://setup. A sign-in page should appear. If you are
unable to connect to the SDG-8622 using either of these shortcuts, you can also enter the IP address of the unit. The
default IP address is 192.168.1.1.
 4. The default username is admin. The password is the account password that was specified during the quick setup.
NOTE
If you have forgotten the password for this device, select Forgot password? and follow the
instructions to reset the gateway configuration to the factory defaults. Next, follow the
instructions under
 5. Select Sign In. The Dashboard page appears, showing data about the system.

Product Specifications

Electrical
Power is provided by a region specific AC to 15V DC power adapter (USB-C) that is included with the SDG-8622. The
nominal output is 15V DC ±5% with a maximum current rating of 3.0 Amps. Regional plug adapter specifications are as
follows:
NOTE
It is strongly suggested that the power supply (a 5.9-foot (1.8 m) power cord) included with the
SDG-8622 be connected to a surge suppressor device which can have its own extension cable.
The surge protection device should provide L-N, L-G, and N-G protection. It is also recommended
that the device contains a visual 'GOOD' indicator.
 
Region
North America
United Kingdom
European Union
Austrailia/New
Zealand
6SDG8622-13A
Using
SmartOS.
Power
120VAC @ 60Hz
NEMA 1-15 Type A, right-angle
230VAC @ 50Hz
220~240VAC @
50Hz
220~240VAC @
Type I, right-angle orientation
50Hz
Connector Type
orientation
Type G
Type C/F
Using SmartOS
Certifications
cULus Listed
UKCA Listed
CE compliant with NB code,
TÜV
RCM Tick Mark, ERAC Listed
6