Download Print this page

Product Specifications - ADTRAN 7310-8 Quick Start Manual

8-channel enterprise lorawan gateway
Hide thumbs Also See for 7310-8:

Advertisement

g
NOTE
You will need to know your PIN before resetting the LoRaWAN gateway to the factory default settings. The PIN will always be the last 5 digits of the
device's serial number, which may not be visible if you have changed your device name from the default. Refer to
on page 3 for more information about the device PIN.
3. To upgrade the LoRaWAN gateway firmware, select the Upgrade Device Firmware option from the Commands list in the System Status menu
(as shown in
Figure
8). Once selected, the LoRaWAN gateway will prompt you to confirm that you want to upgrade the firmware. If the firmware
upgrade is confirmed (by selecting Upgrade when prompted), the firmware upgrade process will automatically begin. Once the upgrade process
has begun, you can close the ADTRAN IoT app session while the firmware upgrade process continues. The firmware upgrade process will take
several minutes to take effect, and the gateway may reboot several times during the upgrade process.
Select the appropriate
option from the
Commands list in the
System Status menu.

Product Specifications

LoRaWAN Interface
■ ISM Band: NA915 (902MHz - 928MHz)
■ Tx Power: 27dBm Max
■ Rx Sensitivity: 127dBm at SF7 BW 125kHz
Electrical
■ Power Supply: 48 VDC, 0.1 A (PoE) or 5 VDC, 1.0 A (micro-USB)
Environment
■ Operating Temperature: 32°F to 104°F (0°C to 40°C)
■ Storage Temperature: -40°F to 158°F (-40°C to 70°C)
■ Relative Humidity: up to 95 percent, non-condensing
f
CAUTION!
Electrostatic Discharge (ESD) can damage electronic devices. When handling devices, wear an antistatic discharge wrist strap to prevent damage to
electronic components. Place in antistatic packing material when transporting or storing. When installing or maintaining, always place devices on an
approved antistatic mat that is electrically grounded.
f
CAUTION!
This product is intended for business deployment. Care should be taken to protect cables from damage or vandalism.
f
CAUTION!
If sufficient ventilation is not provided, the unit could overheat. Do not mount the unit on a heated surface or close to a heat source.
f
CAUTION!
Do not locate the product in direct sunlight or next to any thermal obstructions or source of moisture.
g
NOTE
Changes or modifications not expressly approved by ADTRAN will void the warranty.
6
Figure 8. Restarting, Restoring Defaults, and Upgrading the LoRaWAN Gateway
If Upgrade Device Firmware is
selected, begin the upgrade process
by selecting Upgrade when prompted.
"Connecting to the LoRaWAN Gateway"
617101318F1-13B

Advertisement

loading