Sherwood R-725/RDS Service Manual page 12

Audio/video pro-logic receiver
Table of Contents

Advertisement

Maximize
audio output
IF
1000kHz
1000kHz
Ac voltmeter and
T3
(999kHz)
(999kHz)
oscilloscope to speaker
[AM IFT
terminal of L or R channel
Tuned
1000kHz (999kHz)
| 1000kHz
"Tuned" flag in
Level
800 W/m
(999kHz)
the FL display
bel
aca
nl
OE
wl light on
3-3. FM Alignment
Switch : Press the BAND button to FM and the FM MODE button to MONO
signal
oe
Equipment
Adjustment
Step | Subject
Generator
Frequency
Canneetba
Point
Adjust for
Frequenc
Setting
HUBINS
98.1MHz
98.1MHz
DC Volt meter
Zero reading on
THD
98.1MHz
98. 1MHz
Distortion meter to
Minimize
of L or R channel
Tuned
98.1MHz (98MHz) | 98.1MHz
VR2
"Tuned" flag in
Level
SSG output level :
=p
the FL display
10 W/m
light on
as 4. MPX Alignment
- Signal generator frequency : 98 MHz
* Signal generator deviation : USA: 75kHz.
Europe : 40kHz
> RF signal frequency : 1 kHz
* Signal generator output level : 1000 .V/m
* Connect signal generator to FM antenna terminal through FM dummy antenna (75 &)
Seperation
{8 % Modulation
Pilot on
to 0 dB
Equipment
Connection
AC voltmeter to
speaker terminal
of R channel
AC voltmeter to
AC voltmeter
speaker terminal
reading should be
of L channel
at least 40 dB below
Pilot on
AC voltmeter to
VR3
Set AC voltmeter
speaker terminal
to 0 dB
of L channel
AC voltmeter to
AC voltmeter
speaker terminal
reading should be
of R channel
at least 40 dB below