Shutting The Projector Down; Resetting All Settings - ViewSonic PJ358 User Manual

Viewsonic pj358: user guide
Hide thumbs Also See for PJ358:
Table of Contents

Advertisement

Regarding the indicator lamps (continued)
POWER
LAMP
indicator
indicator
Blinking
In
Red
Turned
or
off
Lghtng
In Red
Lghtng
Smultaneous
In Green
blinking in
Lghtng
In Green
blinking in
NOTE • When the nteror porton has become overheated, for safety
purposes, the projector s automatcally shut down, and the ndcator lamps
may also be turned off. In such a case, dsconnect the power cord, and wat at
least 45 minutes. After the projector has sufficiently cooled down, please make
confirmation of the attachment state of the lamp and lamp cover, and then turn
the power on agan.

Shutting the projector down

Only when the projector can not be turned off by usual
procedure, please push the shutdown swtch usng a
pn or smlar, and dsconnect the power plug from the
power outlet. Before turnng t on agan, wat at least
10 mnutes to make the projector cool down enough.

Resetting all settings

When t s hard to correct some wrong settngs, the FACTORY RESET functon of
the SERVICE tem n the OPTION menu can reset all settngs(except LANGUAGE,
FILTER TIME, LAMP TIME, FILTER MESSAGE and etc.) to the factory default.
ViewSonic
TEMP
indicator
There is a possibility that the interior portion
has become heated.
Please turn the power off, and allow the projector to
cool down at least 20 mnutes. After the projector has
sufficiently cooled down, please make confirmation of
Lghtng
the followng tems, and then turn the power on agan.
In Red
• Is there blockage of the ar passage aperture?
• Is the air filter dirty?
• Does the perpheral temperature exceed 35°C?
If the same ndcaton s dsplayed after the remedy,
please set FAN SPEED of the SERVICE tem n the
OPTION menu to HIGH.
It is time to clean the air filter.
Please mmedately turn the power off, and clean or
change the air filter referring to the section "Air Filter".
Red
After cleaning or changing the air filter, please be sure
to reset the filter timer.
After the remedy, reset the power to ON.
There is a possibility that the interior portion
has become overcooled.
Alternatve
Please use the unt wthn the usage temperature
Red
parameters (5°C to 35°C).
After the treatment, reset the power to ON.
PJ358
Troubleshooting
Description
COMPUTER IN1
Shutdown swtch
K
COMPUTER IN2
63

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents