SECTION
4
SERVICE
MODE
[Liquid Crystal Display All Lit Check Mode]
Procedure:
1.
2
3.
4.
Set to standby state.
Press three buttons of [Ill] (TAPE), [ill] (CD), and[MD/VIDEO]
simultaneously.
Liquid crystal display are all turned on.
To exit from this mode, press the
button to turn the power
OFF.
[Tape Deck Aging Mode]
This mode can be used for operation check of tape deck section.
Procedure:
1.
Set a tape in the tape deck.
2.
Set to standby state.
3. Press three buttons of [Il] (TAPE), [Ml] (CD), and
simultaneously.
4.
The aging is executed in bellow sequence.
5.
Toexit from the aging mode, press the |I/ ©) | button to turn the
power OFF.
Aging mode sequence:
Shut off
1 minute
REC pause for 3 seconds
3 minutes
Fast forward
Shut off
1 minute
[ REC pause for 3 seconds
|
Shut off
3 minutes
[CD Aging Mode]
This mode can be used for operation check of CD section.
Procedure:
1.
Load aCD disc.
2.
Set to standby state.
3. Press three buttons of {il] (TAPE), [Ill] (CD), and
simultaneously.
4.
The aging is executed in bellow sequence.
5.
Toexit from the aging mode, press the [1/7 |button to turn the
power OFF.
Aging mode sequence:
Open the disc tray
Close the disc tray
Play the last track