GENERAL INFORMATION
This installation must conform with local codes or, in
the absence of local codes, in the U.S.A. with the
current National Fuel Gas Code, ANSI Z223.1, and
National Electrical Code ANSI/NFPA 70 installation
codes. In Canada, current CAN/CGA-B 149.1 and
B 149.2 codes and current CSA C22.1 Canadian
Electrical Code.
THIS APPUANCE SHOULD BE INSTALLED,
REPAIRED, INSPECTED BEFORE USE AND AT
LEAST ANNUALLY BY A QUALIFIED SERVICE
PERSON. MORE FREQUENT CLEANING MAY
BE REQUIRED DUE TO EXCESSIVE LINT FROM
CARPETING, ETC. IT IS IMPERATIVE THAT
CONTROL COMPARTMENT, BURNERS AND
CIRCULATING AIR PASSAGEWAYS OF THE
APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE APPLI¬
ANCE SHOULD BE LOCATED OUT OF TRAFFIC
AND AWAY FROM FURNITURE AND DRAPER¬
IES.
WARNING: THIS APPLIANCE CAN ONLY BE
COMMON-VENTED IN ACCORDANCE WITH THE
NATURAL GAS INSTALLATION CODE. THAT IS
THAT THE VENTING MUST BE SIZED ACCORD¬
INGLY TO ACCOMMODATE THE TOTAL BTU
RANGE OF ALL APPLIANCES CONCERNED AND
THAT THE CODE ALLOWS THE VENTING OF
THE APPLIANCES IN QUESTION TO BE VENTED
TOGETHER. IT SHOULD ALSO BE NOTED THAT
GAS APPUANCES MUST NOT BE VENTED WITH
SOLID FUEL BURNING APPUANCES.
Regency ULTIMATE Freestanding Gas Heater
INSTALLATION
WARNING: FAILURE TO INSTALL THIS APPLI¬
ANCE CORRECTLY MAY CAUSE A SERIOUS
HOUSE FIRE AND WILL VOID YOUR WARRANTY.
Provide adequate clearances for servicing, proper
operation and around the air openings into the com¬
bustion chamber. Adequate combustion and ventila¬
tion air must also be provided.
The appliance must be installed on a flat, solid,
continuous surface (e.g. wood, metal, concrete). This
may be the floor, or it can be raised up on a platform
to enhance its visual impact. If the appliance is going
to be installed on carpeting, tile or other combustible
material other than wood flooring, the appliance must
be installed on a metal or wood panel extending the
full width and depth of the appliance. The Regency
Freestanding Gas Stove can be installed in a wide
variety of ways and will fit nearly any room layout. It
may be installed in a recessed position, framed out
into the room, or across a comer.
The ULTIMATE Gas Heater is approved for alcove
installations, which meet the clearances listed below.
This unit can be installed in a bedroom, when installed
with a millivolt thermostat. This unit is not approved
for mobile home installations.
We recommend that you plan your installation on
paper using exact measurements for clearances and
floor protection before actually installing this appli¬
ance. If an existing chimney is not utilized, position
the appliance to allow free passage of factory-built
listed chimney through the ceiling and roof. Have a
qualified building inspector review your plans before
installation.