Mobile Home Installation - Regency F1500 Manual

Wood small stove
Table of Contents

Advertisement

For Canadian Installations: see Outside
Air Kit - Part # 846-502.
There are further requirements when installing
this unit into a mobile home in Canada Only.
Once you have properly marked the position of
your unit and the floor protection as outlined in
the Residential Installation items #1 through #8, a
supply of fresh air has to be supplied to your unit.
See Optional Outside Air Kit instructions in this
manual.
Place your unit in position and secure it to the
floor using two lag bolts 3/8" (10mm) x 3-1/2"
(89mm) through the two holes inside the pedestal
base. It is important to maintain the structural
integrity of the Mobile Home floor, walls and roof
when installing your unit.
For Mobile Home units installed in the U.S. the
unit must be grounded using a #8 ground wire
with approved termination and star washer.
CAUTION: At no time use unlabelled
parts, or substitute parts made for
another chimney system.
Install as per chimney manufacturer's
installation instructions.
1. Identify the position of the outside air damper by the orientation of
the metal handle that rests outside the galvanized pipe. The metal
handle and the damper disc are in line with each other. This means
that if the metal handle is in a horizontal position, the damper is flat
and fully open.
2. Open the damper fully whenever you start a fire. This will allow the
outside air to be drawn in the pedestal base eliminating any potential
smoke escaping the stove and entering the room. (Negative air
pressure)

MOBILE HOME INSTALLATION

Pedestal
Bolted to
Floor
WARNING: Operate only with door
fully closed - open feed door to feed
fire only.
In addition to standard installation instructions
the following requirements are mandatory for
installation in a mobile home.
1. The stove must be permanently bolted to
the floor of the Mobile Home using the floor
screws provided.
2. The stove must have a permanent outside air
source for combustion.
3. The stove must be electrically grounded to
the steel chassis of the Mobile Home.
4. A listed double-wall connector chimney
system, roof thimble, spark arrestor and roof
flashing kit suitable for use in Mobile Homes
must be used.
5. If the chimney exits the Mobile Home at a
location other than through the roof, and
exits at a point 7ft. (2130mm) or less above
the ground level on which the Mobile Home
is positioned a guard or method of enclosing
the chimney shall be fitted at the point of exit
for a height up to 7ft. (2130mm).
6. The chimney shall be attached directly to the
room heater and shall extend at least 3 ft.
Outside Air
(914mm) above the part of the roof through
which it passes. The top of the chimney
should project at least 2ft. (610mm) above
the highest elevation of any part of the Mobile
Home within 10 ft. (3048mm) of the chimney.
7. The chimney system shall comply with Local
Requirements.
8. Any openings in a chimney guard where
required must not permit the entrance of 3/4"
(19mm) diameter rod.
9. CAUTION: THE STRUCTURAL INTEGRITY
OF THE MOBILE HOME ROOF, FLOOR,
W ALLS A ND C E I LI NG MU S T BE
MAINTAINED.
10. Check any other local building code as other
local codes may apply.
11. WARNING: DO NOT INSTALL IN A
SLEEPING ROOM OF A MOBILE HOME.
12. Use silicone to create an effective vapour
barrier at the location where the chimney or
other component penetrates to the exterior
of the structure.
F1500 Wood Stove |
5