Appendix 2 Specification Change Check; Appendix 2-1 Changed Function - Mitsubishi Electric FR-D720 K Series Instruction Manual

Table of Contents

Advertisement

Appendix 2 Specification change check

Check the serial number printed on the rating plate or on the package of the inverter. To find the SERIAL, refer to page 2.

Appendix 2-1 Changed function

(1)
Addition of output signal for the safety function
The change applies to the February 2009 production or later.
 Output of safety monitor output signal 2 (SAFE2) is enabled by setting "81 or 181" to any of Pr.190, Pr.192, Pr.197
(Output terminal function selection). (Refer to page 122.)
 The function of terminal SO is set by Pr.197 SO terminal function selection. (Refer to page 122.)
 Terminal SO can be turned ON/OFF by setting Pr.496 Remote output data 1. (Refer to page 129.)
(2)
Changed operating conditions of the SAFE and SAFE2 signals and addition of the terminal SO monitor
The change applied to the January 2012 production or later.
 E.CPU has been added to the operating conditions of the SAFE and SAFE2 signals used in the safety stop function. 
(Refer to page 27.)
 Monitoring of the terminal SO, which is an I/O terminal, has become available on the operation panel. (Pr.52 = "55"). 
(Refer to page 134.)
 The terminal SO monitor has been assigned to the output terminal monitor bit 7 of RS-485 communication (Mitsubishi
inverter protocol, MODBUS RTU protocol). (Refer to page 198, 211.)
 The SO signal (Pr.197) has been assigned to the inverter status monitor (extended) bit 9 of RS-485 communication
(Mitsubishi inverter protocol). (Refer to page 199.)
 The SO signal (Pr.197) has been assigned to the inverter status bit 9 of the RS-485 communication (MODBUS RTU
protocol). (Refer to page 210.)
(3)
Addition of Pr. 154 Voltage reduction selection during stall prevention operation and Pr. 552 Frequency jump range
This change applies to the March 2014 production or later.
 Pr. 154 Voltage reduction selection during stall prevention operation added. (Refer to page 82.)
 Pr. 552 Frequency jump range added. (Refer to page 87.)