DT-V2000SU
480i 16 : 9 OVER SCAN CONTRAST
•
Test equipment
Signal generator (Cross-hatch pattern:100IRE)
Test points
TP-47G [CRT SOCKET PWB]
Adjustment locations
SC01 (CONTRAST)
1. Set the scan size to OVER, and set the ASPECT to 16: 9 in the MENU screen.
2. Input the 480i signal to the input B terminal.
3. Connect the oscilloscope to the TP-47G.
~
;..
1 vertical cycle
4. Adjust the waveform level between 0% black and 100% white to 30Vp-p with SC01.
··---~
,,L
'
I
I
30Vp-p
I
I
I
'
II
------
•
480P 16 : 9 OVER SCAN CONTRAST
Test equipment
Signal generator (Cross-hatch pattern:100IRE)
Test points
TP-47G [CRT SOCKET PWB]
Adjustment locations
SD01 (CONTRAST)
1. Set the scan size to OVER, and set the ASPECT to 16 : 9 in the MENU screen.
2. Input the 480P signal to the input B terminal.
-
-
3. Connect the oscilloscope to the TP-47G.
~
1 vertical cycle
~
•
4 . Adjust the waveform level between 0% black and 100% white to 30Vp-p with SD01.
··---~
Ill
'
I
I
30Vp-p
I
I
I
I
-- ----
720P 16 : 9 OVER SCAN CONTRAST
•
Test equipment
Signal generator (Cross-hatch pattern:100IRE)
Test points
TP-47G [CRT SOCKET PWB]
Adjustment locations
SE01 (CONTRAST)
1. Set the scan size to OVER in the MENU screen.
2. input the 720P signal to the input B terminal.
-
3. Connect the oscilloscope to the TP-47G.
~
1 vertical cycle
~
4. Adjust the waveform level between 0% black and 100% white to 30Vp-p with SE01.
··---~
,L
I
I
30Vp-p
I
I
I
I
------
•
No.515198