RF Amp Alignment
VHF LO Band
Step
Control Setting
Test Instrument
Adlust
Remarks
Connection
OFF/
VOLUME Contral:
Connect instruments shown
T101
1 ) Select channel 2 and ad-
ON
as
Fig.3.
T102
just T101 and T102 for
SQUELCH
Control:
CCW SWEEP GENERATOR
maximum RF waveform.
6
Select channel 1 through 3. 30-54 MHz.
2)
Check channel 1 thraugh
See Table 1.
3 for maximum output.
A slight deviation as FigA
is acce otable.
VHF AIR Band
Step
Control Setting
Test Instrument
Adlust
Remarks
Connection
OFF/
VOLUME Control:
Same as Step 6 SWEEP
T103
1 ) Select channel 5 and ad-
ON
GENERATOR
108-174
T105
lust T1 03 and T1 05 for
SQUELCH
Control:
CCW MHz.
maximum RF output.
7
Select channel 5 through 6.
2)
Check channel 4 through
See Table 1.
6 for maximum RF output.
A slight deviation as Fig.5
is acceptable.
VHF Hl Band
Step
Control Setting
Test Instrument
Adlust
Remarks
Connection
OFF/
VOLUME Control:
Same as Step 6. SWEEP
T104
1)
Select channel 7 and ad-
ON
GENERATOR
T106
lust T104 and T106 for
SQUELCH
Control:
CCW 136.0005-174 MHz.
maximum RF waveform.
8
Select channel 7 thraugh 9.
2)
Check channel 7 through
See Table 1.
9 for maximum RF output.
A slight deviation as
Fig.6
is acceptable.
UHF LO Band
Step
controt Setting
Test Instrument
Adlust
Remarks
Connection
OFF/
VOLUME Contral:
Same as Step 6 SWEEP TC101
1)
Select
channel
10
and
ON
GENERATOR
380-512
TC102
adlust TC1 01, TC102 and
SQUELCH
Control.
CCW MHz.
TC104
TC 104 for maximum RF
9
Select channel 10 thraugh
output.
12.
2)
Check channel 10 through
See Table 1.
12 tor maximum RF
out-
put. A slight deviation as
Fi .7 is acce otable,
UHF Hl band: No adjustment requlred.
-12 -