Replace Evaporator Blower Motor

1. Unit needs to be removed from sleeve or closet to facilitate fan
replacement. Refer to Chassis Removal
2. Remove electrical box cover.
3. Disconnect the terminals and the P3 cable connector on the indoor
fan motor controller.
Disconnect
3. Remove right side access panel.
4. Remove 10 fan mounting screws.
Remove screws (10 places)
5. Remove four screws on top.
Remove Screws (4 places)
44
COMPONENT TESTING
6. Remove 3 screws on right side.
Remove Screws (3 places)
7. Move inner fan support wall back and slide fan out of the right side of
the unit.
8. Remove 4 allen screws to separate motor from mount.
Remove mounting bolts