Not microphone side
Headband
Cable channel
End piece
1. Put the end piece of the headband (010) into the end piece holder (see figure
below).
2. Completely move down the end piece of the headband (010) to the round/oval
end piece stopper.
Caution:
Do not install the headband cable with a sharpen screwdriver. You can damage the
headband cable. Use only rounded/stub tools.
3. For the microphone side press the headband cable completely into the
headband channel of the end
piece (010). Install the headband cable as shown below.
For the not microphone side first turn the end piece holder to the left side. Then
press the headband cable completely into the headband channel of the end
piece (010). Install the headband cable as shown below and recognize that the
cable routing is on the left side/cable channel side.
4. Snap in the cover.
5. Carefully pull the end of the headband cable to prevent wavy cable routings.
6. Fasten the 2 screws.
7. Check the correct movement of the end piece (010): Move the end piece of the
headband up and down. Ensure that the headband cable is completely inserted
in the cable channel.
Microphone side
Cable
End piece
holder
Cable
Cable
channel
Cable channel
of the end piece
HMD/HMDC/HME 26 Broadcast
Screw