5

Disassembly/Assembly

See also:
See "Exploded view", page 8.
5.1

Disassembly

5.1.1 Removing the earpads
For reasons of hygiene, the earpads should be replaced from time to time. Grasp the
edge of the earpad and pull sharply.
5.1.2 Removing the cap/defective acoustic unit
Note for headsets up to serial number <00200100:
The acoustic units (050/060) have been redesigned. For acoustical reasons always
replace both acoustic units and both earpads (100).
Note for headsets from serial number 00200100:
Replace the defective acoustic unit only (050 or 060). For hygienical reasons the
earpad replacement (100) is recommended.
1. Remove both screws (090) of the acoustic unit (050/060).
2. Carefully put the tip of a small flat-headed screwdriver into the first slot of the
cap (040/070)
.
3. Use the screwdriver to lever the cap (040, 070) to the outer side to unhook the
inner nose.
4. Keep the cap (040, 070) and the acoustic unit (050, 060) under some tension
to prevent a movement of the hook to its old position.
5. Do steps 2 thru 4 again for the second slot
6. Carefully put the tip of a small flat-headed screwdriver at position
and right side near the headband (010).
7. Remove the cap (040/070) from the acoustic unit (050/060) carefully. When
you remove the cap at the microphone side (070), you must make sure that the
leads which are attached to the PCB do not break off.
8. Desolder the microphone arm and the headband leads from the PCB.
5.1.3 Disassembling the microphone arm
See also:
See service information SI 100702-15.
Schraube
Screw
Schraube
Screw
.
on the left
HMD/HMDC/HME 26 Broadcast