Configuring MPE
THE CONFIGURA TION DIALOGUE
The following instructions deal only with configuring an INP. The complete configuration dialogue is
given in the
MPE V System Operation and Resource Mangement Reference Manual.
To begin, log onto the system, define the output files, and initiate a SYSDUMP as shown:
NOTE
Where it is necessary to distinguish user input from computer output in this
configuration dialogue, the user input is underlined.
:HELLO MANAGER.SYS
:FILE T;DEV=TAPE
:FILE L;DEV=LP
:SYSDUMP *T,*L
Step No.
Prompt and Response
ANY CHANGES? YES
2
SYSTEM I D=H P 32002
v. uu .
ff?
(RETURN]
3
MEMORY SIZE?
[RETURN]
4
I/O CONFIGURATION CHANGES? YES
5
LIST I/O DEVICES? YES
or
NO
6
LIST CS DEVICES? YES
or
NO
7
HIGHEST DRT = xx.?
xx
is the current highest hardware device address that can be assigned. Press
[RETURN]
if
xx
is satisfactory. Otherwise, enter a higher DRT number.
Configuration of individual devices begins here.
8
LOGICAL DEVICE
#?
Enter the logical device number of the INP.
A-2