Inspection and maintenance
▶ Check the heat exchanger insulation [2] for cracks, defects on heat
exchanger and replace if necessary according to  Chapter 10.6,
page  10.6.
2
2.
1
1.
Fig. 82 Checking insulation disk
[1]
Insulation protector
[2]
Insulation
9.8

Cleaning/Checking the burner

4
Fig. 83 Burner door assembly
▶ Check the burner [3] for contamination and clean it with a soft brush.
▶ Check the burner [3] for cracks and replace complete burner door
assembly if necessary.
▶ Check the insulation [2] for cracks, defects on burner door and
replace if necessary according to Chapter 10.3, page 62.
▶ Check and inspect electrodes [4] according to Chapter 9.10,
page 59.
▶ Replace the lip seal [1] with a new one and assemble the burner door
to the heat exchanger, making electrical connections according to
Chapter 10.5, page 63.
58
9.9

Cleaning the condensate trap

WARNING
Danger to life due to poisoning!
If the condensate trap is not filled, poisonous flue gas can escape.
▶ Only turn off the trap filling program during maintenance, and turn it
back on at the end of maintenance.
▶ Make sure that the condensate drains off properly.
Ensure to protect the appliance from potential spillage of liquid when
removing the condensate trap.
Damage resulting from an insufficiently cleaned condensate trap are
excluded from the warranty.
▶ Clean the condensate trap regularly.
1
0010045716-001
2
1
2
Fig. 84 Removing the condensate trap - 24kw
3
[1]
Condensate hose
[2]
Condensate trap
1
0010045707-001
2
Fig. 85 Removing the condensate trap - 30kw
[1]
Condensate hose
[2]
Condensate trap
1.
4.
1.
4.