ise MECHANICAL SYSTEM iis
&. Control Panel PCB
Note:
You must adjust the VR for intensity and
AE. (PC320/325/FC230) after replacing
the control panel PCB; see p.. 3-47.
i.
Detaching the Control Pane! PCB
1) Detach the body cover; see p. 4-1.
2)
Disconnect the three connectors ®.
3) Hold the flat cable
@ with both hands,
and detach them from the connector by
lifting them straight up.
4) Disengage the hook @, and detach the
control panel PCB @ by pulling it up.
Figure 4-706
4-18
COPYRIGHT © 1904 CANONINC.
CANON PC300120/225, FC210/290 REV.O JULY 1994 PRINTED IN JAPAN (MPRIME AU JAPON)