5 Adjust Door
Checking Door Alignment
The unit's door is aligned at the factory before shipment.
However, its alignment could have been disturbed during
shipment or during door panel installation.
IMPORTANT
Properly aligned, the door's gasket should be firmly
in contact with the cabinet all the way around the
door (no gaps). Carefully examine the door's gasket
to assure that is is firmly in contact with the
cabinet. Also make sure the door gasket is not
pinched on the hinge side of the door.
1. If the door is properly aligned, go on to 6 Prepare
Power Supply. If it is not, use the following
procedure.
Adjusting Door Alignment
1115R and 1115WC
Units
1. Loosen (do not
remove) top and
bottom hinge
screws. See
Figure 16.
2. Align door squarely
with cabinet. Make
sure gasket is firmly
in contact with
cabinet all the way
around the door (no
gaps).
3. Tighten bottom hinge screws.
4. Tighten top hinge screws. Go on to 6 Prepare Power
Supply.
07/2006
1115R and 1115WC Models
ULIN_0143_
Figure 16
6 Prepare Power Supply
Electrical Specifications
Electrical installation must observe all state and local
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a
qualified electrician.
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current).
An individual, properly grounded branch circuit or circuit
breaker is recommended. GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
a GFCI could be prone to nuisance tripping. However, be
sure to consult your local codes.
See Figure 17 for recommended receptacle location.
Figure 17
SHOCK HAZARD — Electrical Grounding Required.
• Never remove the round grounding prong from
the plug and never use a two-prong grounding
adapter.
• Never use an extension cord to connect power to
the unit.
Go on to 7 Level the Unit.