Adjusting The Stitch Width Control - Pfaff 260 Service Manual

Hide thumbs Also See for 260:
Table of Contents

Advertisement

Do not apply force
in
replacing the barrel as this might cause bending of t,he
com fingers in
the
stitch
width regulating mechanism which,
in
turn, might
cause
hard working of this
mechanism.
The same
trouble is likely
to occur
if
the barrel
is
pushed in, or stands out,
too for.
If
no mark has been mode on
the
machine arm beforehand, turn the zigzag
regulator barrel until
a. on imaginary line drawn
through
the red mark
h
on
the
barrel (Fig. 51)
posses
to
the
right
o·f the hinge stud
located
above it, and
b. needle position lever B points downward when set at its
central
position.
In all three needle
positions,
the rounded tip of the needle position
com
finger
should
be located
in
the middle of
the respective
section of the needle position
com.
To double-check this setting, slightly move the needle position
lever
to the
right and left of
its
central position and check to
see
that the zigzag regulator
arm does not vibrate. Repeat this check with the needle position
lever
set at
its
left and right positions,
respectively.
While on previous machines, the barrel must be pushed into the machine arm
until the set screw enters
the
small groove
in
its
rim,
on recent machines,
it
must be pushed
in
as for
as
it will go.
If stitch width dial A should turn heavily on older machines,
loosen
the set
screw and either push
in
or pull out the barrel slightly. Then
tighten
the set
screw securely.
Replace the second tension spring (b in Fig. 93).
Adjusting the Stitch Width Control
(See
also page 88)
To check
the
correct position of
the
zigzag regulator barrel in
the
machine
arm, turn stitch width dial A to
"0".
The
sideways
movement of the connecting
rod
(105193) must not begin until
stitch
width dial A has been turned clockwise by three or four knurls.
As
you depress finger-tip control F, the connecting rod should move
likewise.
If these conditions ore not met, correct
the
position of
the
barrel
in
the machine
arm.
After the above-mentioned adjustment
has
been mode, also check to
see
that
a. needle position
lever
B points downward when set at its central position,
b. the lobe of eccentric stud B (Fig.
106)
points toward the balance wheel and
the needle bar frame pitman is at its extreme right-hand position,
66