True Food Service Equipment, Inc.
CLEANING THE CONDENSER COIL
When using electrical appliances, basic safety precautions should be followed, including the following
CONDENSER CLEANING:
TOOLS REQUIRED:
• Phillips screwdriver
• Stiff bristle brush
• Adjustable wrench
• Vacuum
A. Disconnect power to unit.
B. Take off rear lower grill assembly by removing
two (2) bottom screws.
If necessary, loosen screws holding the top
pivot pins. Swing grill up and remove frame
hooks from pivot pins at top of louver.
C. Remove bolts anchoring compressor assembly
to frame rails and carefully slide out (tube con-
nections are flexible).
D. Clean off accumulated dirt from condensing
coil with a stiff bristle brush.
E. After brushing condenser coil vacuum dirt
from coil and interior floor.
F. Carefully slide compressor assembly back into
position and replace bolts.
G. Connect unit to power and check to see if
condenser is running.
H. Reinstall louver assembly onto unit, tighten all
screws.