CLEANING THE CONDENSER COIL
When using electrical appliances, basic safety precautions should be
followed, including the following:
TOOLS REQUIRED
Phillips Screwdriver
Stiff Bristle Brush
Adjustable Wrench
STEP 1 - Disconnect power to unit.
STEP 2
SLIDE DOOR MODELS: (See Image 1)
Take off lower grill assembly by removing two (2) screws in
lower corners. (older models may have snap lock tabs instead
of screws).
Loosen screws holding the top pivot pins. Swing grill up and
remove frame hooks from pivot pins at top of louver.
SWING DOOR MODELS: (See Image 2)
Take off lower grill assembly by opening the door and removing
screws from the top of the louver grill. Some models have a
door light switch. Please use caution when removing the grill on
these models. Do not pinch wires. For reinstall, reattach the grill
to the magnets on front of the cabinet and reinstall the screws
on top of the grill.
1
Air Tank or CO2 Tank
Vacuum Cleaner
2
STEP 3 - Remove bolts anchoring compressor assembly to frame
rails and carefully slide out. (tube connections are flexible)
STEP 4 - Clean off accumulated dirt from condensing coil with a
stiff bristle brush.
STEP 5 - Lift cardboard cover above fan at plastic plugs and carefully
clean condenser coil and fan blades.
STEP 6 - After brushing condenser coil vacuum dirt from coil, and
interior floor.
STEP 7 - Replace cardboard cover. Carefully slide compressor
assembly back into position and replace bolts.
STEP 8 - Reinstall louver assembly onto unit with appropriate
fasteners and clips. Tighten all screws.
STEP 9 - Connect unit to power and check to see if condenser is
running.
.
.