B General

POSITION
Program Items
B1
Tank Temp.
B2
Brew at Temp.
Show Tank
B4
Temperature
Units of Measure
B5
TEMPERATURE
Units of Measure
B6
VOLUME
B7
Customer Name
B8
Customer Name
B9
Demo Mode
B10
Eco Mode
B11
Eco Idle Time
B12
Eco Idle Temp
B13
Water Filter
BREW AT TEMPERATURE DEFINITIONS
DEFAULT: BREW AT TEMP: "ON"
(FACTORY DEFAULT FOR BREWER)
"BREW at TEMP:
-Batch will not start if tank temperature
is below set point.
-Display will show "HEATING"
and hot water tank temperature
The "BREW START" entry buttons will not
illuminate until the hot water tank reaches the
selected temperature.
Controls allow both sides of dual brewer to
operate if one side has an ongoing brew
started and the second side brew is selected.
Notifications shown on screen:
TEXT: HEATINGTank above 87°C/189°F-will
allow brew at low temperature.
Coffee flavor may be affected
TEXT: L. HEATTank above 77°C/170°F-
will allow brew at low temperature.
Coffee flavor will be noticeably affected
USER SELECTABLE OPTION: BREW AT TEMP: OFF
(Not recommended) Unit will operate at lower temperature
Allows brewing at any temperature above 77°C/170°F
Below 70°C/170°F The brewer will display "HEATING"
Go to fetco.com for the latest versions of all information
Brewer Operation Control Settings, Adjust Brew Flow Rate
Factory set Default
Programming Range
200°F-or-93° C
NOTE: Equipment is
Fahrenheit by default
"YES"
YES
F°-Fahrenheit
Fahrenheit/Celsius
G-Gallons
Gallons/Liters/Ounces
Off
(only if above is "ON)
Scroll with batch keys
DEMO ON/OFF
On
1Hr
170°F
OFF
Hot water tank not
at brew temp
setpoint.
Tank temp
STOP is not lit 
BREW START
buttons not lit.
and are disabled.
When hot water
tank temperature
is at setpoint.
Buttons will
illuminate and
"READY" will be
displayed
Increments
77° to 97°C
0.5°C
170°F to 207°F
1.0°F
ON/OFF
YES/NO
YES/NO
Gal/L/Oz
NO or YES
A-Z;a-z;0-9
ON/OFF
YES/NO
1-6 hours
1 hour
158-176°F
1 degree
ON/OFF
YES/NO
Chart to correct for altitude for boiling point
[ft]
[m]
vv
vv
vv
0
0
500
152
HEATING
1000
305
160°F
2000
610
2500
762
STOP
STOP
3000
914
3500
1067
4000
1219
4500
1372
5000
1524
5500
1676
6000
1829
6500
1981
7000
2134
7500
2286
8000
2438
8500
2591
User Guide & Operator instructions
Page 7
Notes
Chart to correct for
high altitude below
SEE NOTE BELOW
To display HW tank
temperature on screen
NOTE: Overwrites
C/F
user settings
(see page 9)
NOTE: Overwrites
user settings
(see page 9)
For name on screen
16 characters total
Demonstrates the controls
for training. Disables all
components in demo mode
If Selected: Lowers hot
water tank temperature after
preset time of inactivity
Time of inactivity to go into
ECO Mode
Temperature that hot water
tank is lowered to
Water filter life is accessed
in G-Counters. This is user
set and will display indicator
to change water filter
in tank water temperature.
Suggested
Boiling
Suggested
Setting[°F]
point[°F]
Setting[°C]
point [°C]
205
212.0
96
205
211.0
96
200
210.1
93
200
208.1
93
200
207.2
93
200
206.2
93
197
205.3
92
195
204.3
91
194
203.4
90
194
202.4
90
193
201.5
89
192
200.6
89
191
199.6
88
190
198.7
87
188
197.8
86
187
196.9
86
185
196.0
85
P214 September 2023
Boiling
100.0
99.5
98.9
97.8
97.3
96.8
96.3
95.7
95.2
94.7
94.2
93.6
93.1
92.6
92.1
91.6
91.1