B GENERAL

POSITION
Program Items
B1
Tank Temp.
B2
Brew at Temp.
B3
LLC Sensitivity
B4
Temperature Scale
B5
Volume Scale
LEFT brew valve
B6
Flow Rate:
RIGHT brew valve
B7
Flow Rate:
Low flow rate
B8
from mains
BREW AT TEMPERATURE DEFINITONS
--------------------------------------------------------------------------------------------------------
-
DEFAULT: BREW AT TEMP: "ON"
(FACTORY DEFAULT FOR BREWER)
"BREW at TEMP:
-Batch will not start if tank temperature is
below set point.
-Display will show "HEATING" and hot
water tank temperature
The "BREW START" entry buttons will not
illuminate until the hot water tank reaches
the selected temperature.
Control will allow both sides of dual brewer to operate if one side has
an ongoing brew started and the second side brew is selected.
Notifications shown on screen:
TEXT: HEATINGTank above 87°C/189°F-will allow brew at low
temperature. Coffee flavor may be affected
TEXT: L. HEATTank above 76°C/169°F-will allow brew at low
temperature. Coffee flavor will be noticably affected
------------------------------------------------------------------------------------------------------
USER SELECTABLE OPTION: BREW AT TEMP: OFF
Allows brewing at any temperature above 77°C/170°F
Below 70°C/170°F The red colored ready lights switch turn off-unit
will operate at cold
Use this formula to compensate for minor discrepancies in actual volume versus programmed volume.
Use the formula above to determine the correct setting Set lower to increase volume, higher to decrease volume.
See "PROGRAM" B5 and B6 For valve settings and calibration. Factory set brew valve flow rates are in liter/min
Go to fetco.com for the latest versions of all information
Brewer Operation Control Settings, Adjust Brew Flow Rate
Factory set Default
93° C -or- 200°F
NOTE: Equipment
is metric by default
"YES"
LOW
°C
Degrees Celsius
Liters [Gallons]
CBS-1152
3.40L/0.9G
CBS-1151&1152
3.40L/0.9G
NO
Hot water tank
not at temp.
Tank temp
STOP is not lit 
BREW START
buttons not lit.
and are disabled.
Buttons will
reilluminate when
"READY"
(Not recommended)
Programming
Range
70° to 96°C
157°F to 205°F
ON/OFF
LOW is
"normal" for
most water
"HIGH" for R.O.
Equipment is
metric by default
Equipment is
metric by default
2.9-3.9Liter
0.73-1.01Gallon
2.9-3.9Liter
0.73-1.01Gallon
OFF/ON
HEATING
160°F
STOP
STOP
Default Brew Valve Flow Rate—All CBS-1150 V+ Brewers
CBS-1151 &CBS-1152
Left and Right Brew Valve FR
Page 7
Increments
Notes
See below
0.5°C
for chart to correct
1.0°F
for high altitude
YES/NO
SEE NOTE BELOW
Liquid level control
LOW
sensitivity.
or
High is for reverse
HIGH
osmosis water or very
pure water.
[Switchable Units]
C/F
L/Gal
[Switchable Units]
0.50L
Adjusts flow rate
0.01Gal
0.50L
Adjusts flow rate
0.01Gal
Toggle =/-
Trims fill system for
YES or NO
low supply
Chart to correct for altitude for boiling point
in tank water temperature.
Suggested
Boiling
Suggested
[ft]
[m]
Setting[°F]
point[°F]
Setting[°C]
0
0
205
212.0
500
152
205
211.0
1000
305
200
210.1
2000
610
200
208.1
2500
762
200
207.2
3000
914
200
206.2
3500
1067
197
205.3
4000
1219
195
204.3
4500
1372
194
203.4
5000
1524
194
202.4
5500
1676
193
201.5
6000
1829
192
200.6
6500
1981
191
199.6
7000
2134
190
198.7
7500
2286
188
197.8
8000
2438
187
196.9
8500
2591
185
196.0
ml/min
Range
3400 ml
+2903 to 3900ml
P167 November 2017
Boiling
point [°C]
96
100.0
96
99.5
93
98.9
93
97.8
93
97.3
93
96.8
92
96.3
91
95.7
90
95.2
90
94.7
89
94.2
89
93.6
88
93.1
87
92.6
86
92.1
86
91.6
85
91.1