Ratings And Performance - Omron F3S-B122P-L Instruction Manual

Safety light curtain
Table of Contents

Advertisement

F3S-B

1-7 Ratings and Performance

Type
F3S-B
Stand-alone
Item
No. of optical axes
12 to 66 6 to 33
Optical-axis pitch
25 mm
Non-transparent:
Optical resolution
(Detection capability)
30 mm
300 / 450 / 600 / 750 / 900 / 1,050 / 1,200 / 1,350
Protective height
/ 1,500 / 1,650 mm
Detection distance 0.3 to 5.0 m
ON to OFF : See "1-10 Table of Response Time"
Response time
OFF to ON (*2): Default 100 ms (selectable with F39-U1E, 80 to 400 ms)
Startup waiting
2 s max.
time
Supply voltage: Vs 24 VDC ± 20% (including 5 Vp-p ripple)
Current
400 mA max. (under no-load conditions)
consumption
Light source
Infrared LED (880 nm wavelength). Lifetime: 50,000 hrs. at 25 °C.
Effective
Within ± 5° for the emitter and receiver at a detection distance of at least 3 m
aperture angle
according to IEC 61496-2
Operating mode
Light ON
Two PNP transistor outputs, operational current (load current) 200 mA max., re-
Control output
sidual voltage 2 V max. (except for voltage drop due to cable extension)
PNP transistor output (not safety-related control output),
Instability output
load current 100 mA max., residual voltage 2 V max. (except for voltage drop due
to cable extension)
Protection circuit
Output short-circuit protection, power supply reverse connection protection
Mode selection before power ON by connecting "Interlock selection input" line to:
Start/restart
interlock function
Mode selection by connecting "External test input" line to:
External
test function
Default inactive, selectable with F39-U1E
Relay monitoring input line with NC contact connected,
Relay monitoring
function (Optional)
Start interlock
Default inactive, selectable with F39-U1E
function (Optional)
Blanking function
Default inactive, selectable with F39-U1E
(Optional)
Indicators
See "1-8 Indicators"
Connection
For Extension cable
method
For Series connection cable
Ambient
During operation : –10 to 55 °C (with no freezing)
temperature
During storage
During operation : 35 to 85 %RH (with no condensation)
Ambient humidity
During storage
Insulation
20 MΩ min. (at 500 VDC)
resistance
Dielectric strength
1,000 VAC 50/60 Hz for 1 min
voltage
12
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
P (*1)
4 to 22 12 to 66 6 to 33
50 mm
75 mm
in diameter
55 mm
80 mm
Active
: No connection or 0 to 2.5 VDC, 3 mA max.
Inactive
: Instability output line
Reset of start/restart interlock by connecting "Interlock selection input" line to:
Interlock reset
: 17 VDC to Vs, 20 mA max. Duration time 15 to 2,500 ms
Active
: 17 VDC to Vs, 10 mA max. Duration time at least 15 ms
Inactive
: No connection or 0 to 2.5 VDC, 2 mA max.
Available level
Allowed relay delay time (*2)
Termination when not selected
: –25 to 70 °C
: 35 to 95 %RH
F3S-BM
P
(*1)
Master unit for series
connection
4 to 22 12 to 30 6 to 15
25 mm
50 mm
75 mm
30 mm
55 mm
80 mm
: 17 VDC to Vs, 10 mA max.
: Selectable between 20 and 300 ms
: No connection or 0 to 2.5 VDC, 2 mA max.
: 8 pins, M12 connector
: 6 pins, M12 connector
F3S-BS
(*1)
Slave unit for series
connection
4 to10
25 mm
50 mm
75 mm
30 mm
55 mm
80 mm
300 / 450 / 600 / 750 mm