Graco 395 Repair Manual page 14

Airless sprayers
Hide thumbs Also See for 395:
Table of Contents

Advertisement

On/Off Switch Replacement
110, 240 Vac (See page 1 for models)
Removal
1.
Relieve pressure; page 4.
2. Fig. 11. Remove four screws (12) and pressure
control cover (50).
3. Remove display connector (B) from plug (C).
4. Disconnect four wires (A) from ON/OFF
switch (58).
5. Remove toggle boot (30) and locking ring. Remove
ON/OFF switch (58).
14
309674
Installation
1. Install new ON/OFF switch (58). Install locking ring
and toggle boot (30).
2. Connect four wires (A) to ON/OFF switch (58).
3. Install display connector (B) in plug (C)
4. Install pressure control cover (50) with four
screws (12).