To find Fluid Outlet Pressure (psi/MPa/bar) at a
specific fluid flow (gpm/lpm) and operating air pressure
(psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Follow vertical line up to intersection with selected
fluid outlet pressure curve.
3. Follow left to scale to read fluid outlet pressure.

Performance Charts

Husky 205 Fluid Outlet Pressure
Test Conditions:
Pump tested in water with inlet submerged.
FLUID FLOW--gpm (lpm)
www.northridgepumps.com
Fluid Pressure Curves
at 100 psi (0.7 MPa, 7 bar) air pressure
A
at 70 psi (0.48 MPa, 4.8 bar) air pressure
B
at 40 psi (0.28 MPa, 2.8 bar) air pressure
C
308652ZAM