Wired Measurement Using Flash Unit With Synchro Cord - Sekonic DIGI MASTER L-718 Operating Instructions Manual

Hide thumbs Also See for DIGI MASTER L-718:
Table of Contents

Advertisement

16
Wired Measurement using Flash Unit
with Synchro Cord
Wired measurement
is
recommendable when you measure the flash light
from the subject
position,
or when the meter fails to register flash light in
wireless
(cordless) measurement;
for
example,
close to
a
fluorescent
lamp,
or in high ambient
condition,
and so forth
.
(1) Switch the meter ON and set the
mode selection key at the position
)
c
.
The symbol of
Dc
is
indicated on the display
(Fig
.
17).
(2) Set the film speed (ISO) and shutter
speed (T) as shown in the
paragraphs for
"
Preparing the Meter
for
Operation".
(3) Connect the synchro cord to the
synchro terminal of meter and the
flash unit.
(4)
Point
the Lumisphare accurately
toward the camera from the
subject
position
,
and press the measuring
switch to fire the flash
.
(5) The appropriate F-stop value is
displayed on the meter
(Fig.
18).
For repeat measurement, press the
measuring switch again
.
<
NOTE
>
The notes for wireless measu rement
are also applicable to wi red
measurement.
lin
u
H
ISO
,no
IU
125
1 1 4 2 2.8 4 5
6
8 11
18
22 32
45 84 90
Dc
I_®L
-¢;
(
(U
1
1111111
1
»)
(Fig
.
17)
ISO
,no
IU
2 32 45 64 90
(Fig
. 18)
16
Wired Measurement using Flash Unit
with Synchro Cord
Wired measurement
is
recommendable when you measure the flash light
from the subject
position,
or when the meter fails to register flash light in
wireless
(cordless) measurement;
for
example,
close to
a
fluorescent
lamp,
or in high ambient
condition,
and so forth
.
(1) Switch the meter ON and set the
mode selection key at the position
)
c
.
The symbol of
Dc
is
indicated on the display
(Fig
.
17).
(2) Set the film speed (ISO) and shutter
speed (T) as shown in the
paragraphs for
"
Preparing the Meter
for
Operation".
(3) Connect the synchro cord to the
synchro terminal of meter and the
flash unit.
(4)
Point
the Lumisphare accurately
toward the camera from the
subject
position
,
and press the measuring
switch to fire the flash
.
(5) The appropriate F-stop value is
displayed on the meter
(Fig.
18).
For repeat measurement, press the
measuring switch again
.
<
NOTE
>
The notes for wireless measu rement
are also applicable to wi red
measurement.
lin
u
H
ISO
,no
IU
125
1 1 4 2 2.8 4 5
6
8 11
18
22 32
45 84 90
Dc
I_®L
-¢;
(
(U
1
1111111
1
»)
(Fig
.
17)
ISO
,no
IU
2 32 45 64 90
(Fig
. 18)