6. POSITIONING IN THE COUNTER TOP

The following operation requires building and/or carpentry work so must be
carried out by a competent tradesman.
Installation can be carried out on various materials such as masonry, metal,
solid wood or plastic laminated wood as long as they are heat resistant (T
90°C).
6.1
Fixing to the supporting structure
Create an opening with the dimensions shown in the figure in the top surface of
the counter, keeping a minimum distance of 50 mm from the rear edge.
This appliance can be mounted against walls higher than the work surface on
condition that a distance of "X" be kept between the appliance and the wall as
shown in the figure so as to avoid damage from overheating. Make sure that
there is a minimum distance of 750 mm between the stoves and any shelf that
may be installed directly above it.
*:this amount (150) refers to the distance that should be maintained if your appliance is equipped with
a "double crown" burner with a capacity of 4.95 kW.
Carefully position the supplied insulating seal on the outer perimeter of the hole
made in the counter top as shown in the figures below, trying to make it stick on
the entire surface by applying light pressure on it with your hands. Depending
on the hob model being installed refer to the dimensions in the figure, bearing in
mind that for both models the long front side must brush against the hole. Fix
the hob to the unit using the appropriate brackets A supplied. Carefully trim the
surplus away from edge B beyond the seal.
The dimensions given in the following drawing refer from the hole to the inside
of the seal.