Kenwood NX-220 K Service Manual page 68

Vhf digital transceiver
Table of Contents

Advertisement

NX-220
Item
Panel tuning mode
DTMF
1) Adj item: [DTMF]
Deviation
Adjust: [✳✳✳.✳.]
*4
PTT: ON
Press [B] key to
[Wide 4k]
store the adjust-
ment value.
[Wide 5k]
1) Adj item: [DTMF]
Adjust: [✳✳.✳.✳.]
PTT: ON
Press [B] key to
store the adjust-
ment value.
10. Single
1) Adj item: [TONE]
Tone
Adjust: [✳✳✳✳.]
Deviation
Deviation meter
*4
LPF: 15kHz
HPF: OFF
[Narrow]
PTT: ON
Press [B] key to
store the adjust-
ment value.
[Wide 4k]
1) Adj item: [TONE]
Adjust: [✳✳✳.✳.]
PTT: ON
Press [B] key to
store the adjust-
ment value.
[Wide 5k]
1) Adj item: [TONE]
Adjust: [✳✳.✳.✳.]
PTT: ON
Press [B] key to
store the adjust-
ment value.
11. MSK
1) Adj item: [MSK]
Deviation
Adjust: [✳✳✳✳.]
*4
Deviation meter
LPF: 15kHz
[Narrow]
HPF: OFF
PTT: ON
Press [B] key to
store the adjust-
ment value.
68
ADJUSTMENT (E TYPE)
Condition
PC test mode
equipment
1) Adj item: [DTMF
Deviation
Deviation (Analog
meter
Wide 4k)]
Oscilloscope
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [DTMF
Deviation (Analog
Wide 5k)]
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [Single
Tone Deviation
(Analog Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [Single
Tone Deviation
(Analog Wide 4k)]
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [Single
Tone Deviation
(Analog Wide 5k)]
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [MSK
Deviation (Analog
Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Measurement
Test-
Unit Terminal Unit
Panel
ANT
Panel
Adjustment
Specifi cations /
Parts
Method
[Panel
Write the value as
2.00kHz±0.05kHz
tuning
followings.
mode]
540 (Reference
Selector
value)
[PC test
mode]
[ ],[ ]
2.50kHz±0.05kHz
Write the value as
1.50kHz±0.05kHz
followings.
513 (Reference
value)
2.40kHz±0.05kHz
3.00kHz±0.05kHz
Write the value as
1.50kHz±0.05kHz
followings.
513 (Reference
value)
Remarks

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-220Nx-220 e3Nx-220 k2Nx-220 e2Nx-220 k3Nx-220 e