Kenwood NX-220 K Service Manual page 49

Vhf digital transceiver
Table of Contents

Advertisement

Item
Panel tuning mode
12. CW ID
1) Adj item: [CWID]
Deviation
Adjust: [✳✳✳✳]
*4
Deviation meter
LPF: 15kHz
[NXDN
HPF: OFF
Very
PTT: ON
Narrow]
Press [B] key to
store the adjust-
ment value.
*4: Refer to the "Necessary Deviation adjustment item for each signaling and mode" table on page 50.
13. Battery
1) Adj item: [BATT]
Warning
Adjust: [✳✳✳]
Level
PTT: ON
writing
14. Battery
[Panel test mode]
Warning
1) CH-Sig: 1-1
Level
BATT terminal
check
voltage: 6.0V while
transmitting
ADJUSTMENT (K TYPE)
Condition
PC test mode
equipment
1) Adj item: [CW ID
Deviation
Deviation (NXDN
meter
Very Narrow)]
Oscilloscope
Deviation meter
LPF: 15kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [Battery
Power meter
Warning Level]
DVM
PTT: Press
[Transmit] button.
1) Test Channel
Channel: 1
Test Signaling
Mode: Analog
Signaling: 1
BATT terminal
voltage: 6.0V while
transmitting
Measurement
Test-
Unit Terminal Unit
Panel
ANT
Panel
Panel
ANT
BATT
terminal
NX-220
Adjustment
Specifi cations /
Parts
Method
[Panel
Write the value as
1.00kHz±0.10kHz
tuning
followings.
mode]
376 (Reference
Selector
value)
[PC test
mode]
[ ],[ ]
Press the PTT
switch or [Transmit]
button on the PC
window.
Apply 6.20V to
battery terminal.
Confi rm that one
pre-determined nu-
meric in the range 1
to 256 appears.
[Panel tuning mode]
Press [B] key to
store the adjust-
ment value.
[PC test mode]
Press [Apply] but-
ton to store the
adjustment value.
Check
The transceiver
can transmit with
causing the LED to
blink.
Remarks
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-220Nx-220 e3Nx-220 k2Nx-220 e2Nx-220 k3Nx-220 e