Structure Menu - Riello Condexa HPR 35 Instructions For The Installer And For The Technical Assistance Centre

Table of Contents

Advertisement

The following table lists the programmable parameters; if the adjustment board does not support the relative func-
tion, the interface returns an error message.

1.13 Structure menu

For a detailed explanation of the parameters, refer to paragraph "1.14 Description of the parameters".
Parame-
Scrolling message
Menu
ters
only if parameter P1.05 = 1
P1
SETTINGS
P1.01
LANGUAGES
P1.02
TIME
TIME PROGRAM
P1.03
SCROLLING
P1.05
P3
CONFIGURATION
HYDRAULIC CONFIGURATION
P3.01
P3.02
WATER PRESSURE TRANSDUCER 0 / 1
AUTO FILL ENABLE
P3.03
BEGIN SYSTEM FILLING
P3.04
AIR PURGING CYCLE
P3.05
MIN FAN SPEED
P3.06
MAX FAN SPEED
P3.07
P3.08
SLOW IGNITION ADJUSTMENT
MAX FAN SPEED HTG
P3.09
RANGE RATED
P3.10
CONFIG AUX
P3.11
EXHAUST PROBE RESET
P3.12
IGNITION SPEED IN RESTART
P3.13
AFTER SHUTDOWN DUE TO
TEMPERATURE
P4
HEATING
HYST OFF HIGH TEMP
P4.01
P4.02
HYST ON HIGH TEMP
HYST OFF LOW TEMP
P4.03
P4.04
HYST ON LOW TEMP
PUMP CONTROL TYPE
P4.05
OT+ CASCADE CONTROL
P4.08
P4.09
SCREED FUNCTION
ANTI CYCLE FUNCTION
P4.10
P4.11
RESET CH TIMERS
MAIN ZONE ACTUATION TYPE
P4.12
P4.13
MAIN ZONE BE16 ADDRESS
MAIN ZONE HYDRAULIC CONF
P4.14
P4.15
MAIN ZONE LOW TEMP
P4.16
MAX CH SET
MIN CH SET
P4.17
HT = HIGH TEMPERATURE ● LT = LOW TEMPERATURE
(°)
0 = HEATING ONLY - 1 = INSTANTANEOUS BOILER WITH FLOW SWITCH - 2 = INSTANTANEOUS BOILER WITH FLOW METER -
3 = STORAGE TANK WITH PROBE - 4 = STORAGE TANK WITH THERMOSTAT
Value
6 ES
0 IT
1 RO
7 EL
2 FR
8 BG
3 EN
9 PL
4 SR
10 SL
5 HR
NOT AVAILABLE
0 / 1
0 / 1 / 2 / 3 / 4
0 / 1
NOT AVAILABLE ON THIS MODEL
0 / 1
1.200-3.600
3.700-9.999
MIN-MAX
MIN - MAX
NOT AVAILABLE ON THIS MODEL
0 / 1 / 2
0 / 1
MIN FAN SPEED/ SLOW IGNITION
ADJUSTMENT
2 - 10
2 - 10
2 - 10
2 - 10
60 - 100
NOT AVAILABLE ON THIS MODEL
0 / 1
0 - 20 min
0 / 1
0 / 1
1 - 6
0 / 1
0 / 1
HT: MIN CH SET - 80
LT: MIN CH SET - 45,0
HT: 20 - MAX CH SET
LT: 20 - MAX CH SET
15
GENERAL REMARKS
Password
Value set
level
in the factory
USER
USER
0
USER
INSTALLER
0 (°)
SERVICE
1
SERVICE
0
SERVICE
1
see technical data
INSTALLER
table
see technical data
INSTALLER
table
see technical data
INSTALLER
table
see technical data
INSTALLER
table
INSTALLER
0
INSTALLER
0
min value between
INSTALLER
3.600 rpm and P308
SERVICE
5
SERVICE
5
SERVICE
3
SERVICE
3
INSTALLER
85
INSTALLER
0 (
boiler in OFF and P4.15=1)
INSTALLER
3 min
INSTALLER
0
INSTALLER
0
INSTALLER
3
INSTALLER
0
INSTALLER
0
80
INSTALLER
45,0
40
INSTALLER
20
Personali-
sed
values