System Configuration; Mounting - Furuno PR-241 Installation Manual

Ac/dc power supply unit
Table of Contents

Advertisement

Optional Supply
Name
Ferrite Core

SYSTEM CONFIGURATION

System configuration for single use
Backup
Battery
24 VDC
: Standard supply
: Optional or local supply
System configuration for dual use
Backup
Battery
24 VDC
: Standard supply
: Optional or local supply

1. MOUNTING

This unit can be mounted on a desktop or bulkhead. Refer to outline drawing in the back of
this manual when you mount the unit.
When mounting the unit, pay attention to the following points.
• This unit has the following ingress-proof ratings: IP22 for desktop mounting, IP20
for wall mounting.
• When using in dual, do not input from multiple AC power supplies or batteries. Due
to the difference in the load characteristics of the battery and the PR-241, it may not
function as a power supply.
• When using in dual, do not stack the units. Always leave sufficient space between
the units to allow for air-flow and prevent heat build-up. See the outline drawing at
the back of this manual for minimum distances required.
• Turn off the power at the switchboard before beginning the installation.
• Referring to the outline drawings at the back of this manual, leave sufficient room
for service and maintenance.
Type
OP86-11
001-594-450
DPYC-1.5
DPYC-2.5
AC/DC Power Supply
DPYC-2.5
TTYCSLA-1
AC/DC Power Supply
Code No.
Qty.
1
AC/DC Power Supply
Unit
PR-241
TPYC-1.5
100-230 VAC
Unit
PR-241
TPYC-1.5
Unit
PR-241
2
Remarks
EMI Cores (GRFC-10, 7
pcs. and GRFC-13, 3 pcs)
Connected
DPYC-1.5
Equipment
(Up to 10 A)
Connected
DPYC-2.5
Equipment
(Up to 20 A)
TPYC-1.5
100-230 VAC
DPYC-2.5