Furuno PR-241 Installation Manual

Ac/dc power supply unit

Advertisement

Installation Guide
AC/DC POWER SUPPLY UNIT
PR-241
Model
SAFETY INSTRUCTIONS ................................................................................................ i
OVERVIEW ...................................................................................................................... 1
EQUIPMENT LIST ........................................................................................................... 1
SYSTEM CONFIGURATION ........................................................................................... 2
1. MOUNTING.................................................................................................................. 2
2. WIRING FOR SINGLE USE ........................................................................................ 3
3. WIRING FOR DUAL USE ............................................................................................ 5
4. HOW TO USE THE UNIT ............................................................................................ 9
5. JIS CABLE GUIDE .................................................................................................... 10
SPECIFICATIONS ..................................................................................................... SP-1
OUTLINE DRAWINGS ................................................................................................ D-1
INTERCONNECTION DIAGRAMS.............................................................................. S-1
www.furuno.com
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.

Advertisement

Table of Contents
loading

Summary of Contents for Furuno PR-241

  • Page 1: Table Of Contents

    Installation Guide AC/DC POWER SUPPLY UNIT PR-241 Model SAFETY INSTRUCTIONS ....................i OVERVIEW ........................1 EQUIPMENT LIST ......................1 SYSTEM CONFIGURATION ................... 2 1. MOUNTING........................2 2. WIRING FOR SINGLE USE ..................3 3. WIRING FOR DUAL USE .................... 5 4.
  • Page 2: Safety Instructions

    Warning label(s) is(are) attached to the unit. Do not remove the label(s). If a label is missing Use only the specified power or damaged, contact a FURUNO agent or cable. dealer about replacement. Fire or damage to the equipment...
  • Page 3: Overview

    OVERVIEW The PR-241 is a unit integrates the functions of our AC/DC power supply units and rectifiers listed below. • AC/DC power supply unit PR-240, PR-300 • Rectifier unit RU-1746B-2, RU-3423, and RU-3424. Important notices The specifications of PR-241 have been changed to be compatible with DC bypass. The DC compatible unit has a white dot as shown in the figure below.
  • Page 4: System Configuration

    • When using in dual, do not input from multiple AC power supplies or batteries. Due to the difference in the load characteristics of the battery and the PR-241, it may not function as a power supply.
  • Page 5: Wiring For Single Use

    The mounting procedure is as follows: 1. Referring to the outline drawing at the back of this manual, make four pilot holes for self-tapping screws (4x16, local supply) in the mounting location. 2. Place the unit in a fixed position and align the screw holes. 3.
  • Page 6 Fabrication of TPYC-1.5 Inner sheath Drain wire Drain wire Armor Pass the heat shrinkable tube (local supply) onto the drain wire. Attach the crimp-on lug (FV2-P4K) to the core. Vinyl tape Fabrication of DPYC-1.5 Inner sheath Armor Attach the crimp-on lug (FV2-P4K) to the core.
  • Page 7: Wiring For Dual Use

    2. Unfasten the binding screws on the terminal and attach the fabricated following cables to the appropriate terminal. • TPYC-1.5 (Power cable from ship’s main) • DPYC-1.5 (Power cable from backup battery) Binding screws TPYC-1.5 DPYC-1.5 (Cable from Ship’ s main) Cable from Backup battery 3.
  • Page 8 Fabrication of TPYC-1.5 Note: Attach the Ferrite cores as close as possible to the unit. Inner sheath Drain wire Drain wire Armor Pass the heat shrinkable tube (local supply) onto the drain wire. Attach the crimp-on lug (FV2-P4K) to the core. Vinyl tape Attach the ferrite core Attach with no...
  • Page 9 Fabrication of TTYCSLA-1 Note: Attach the Ferrite cores as close as possible to the unit. Inner sheath Armor Attach the crimp-on lug (FV1.25-M3(LF) RED K) to the core. Vinyl tape Attach the ferrite core . (GRFC-10, optional supply) Installations for dual use, make the necessary connections with the following procedure.
  • Page 10 3 mΩ or less. In the case the connected In the case the connected equipment is single equipment is multiple PR-241 PR-241 PR-241 PR-241 (Main) (Sub)
  • Page 11: How To Use The Unit

    4. HOW TO USE THE UNIT Use the power switch to turn this unit on. Power Switch Breaker After turning on the power switch, the LED lights up as follows: • AC is selected as the input: Green • Battery is selected as the input: White •...
  • Page 12: Jis Cable Guide

    EX: TTYCYSLA - 4 MPYC - 4 # of cores Designation type Designation type # of twisted pairs TTYCSLA-4 The following reference table lists gives the measurements of JIS cables commonly used with Furuno products: Cable Core Core Cable Diameter Diameter...
  • Page 13: Specifications

    FURUNO PR-241 SPECIFICATIONS OF AC/DC POWER SUPPLY UNIT PR-241 GENERAL Rated input voltage 100-230 VAC, 1 phase, 50-60 Hz and 24 VDC from backup battery Input current under no-load 0.8 A max. (60 Hz), 1.0 A max. (50 Hz) Rated output voltage 24 VDC±5%: 10 A max.
  • Page 15 28/May H.MAKI...
  • Page 16 FURUNO PR-241 AC/DC 電源ユニット PR-241 仕 様 1.総合 (1) 定格入力 AC100-230 V、単相、50-60 Hz および DC24 V(バックアップ電源) (2) 無負荷時入力電流 0.8 A 以下(60 Hz)、1.0 A 以下(50 Hz) (3) 定格出力 DC24 V ±5%: 10 A 以下(最大 2 台まで機器接続可) (4) LED 表示 入力電源の状態表示(AC:緑、DC:白) (5) 保護機能...
  • Page 17 2 台で使用する場合の手順 注 1) 「ID SW」 、および「Terminate SW」の各スイッチは使用しないでください。 注 2)本機のブレーカが切れる恐れがあるため、接続されている機器の電流の 合計が 20A 以内であることを確認してください。 本機を 2 台で使用す る 場合の手順は、 以下の通 り です。 注)この手順通りに行わないと、本機のブレーカが切れる恐れがあります。 1. メインの電源スイッチをオンにします。 2. サブの電源スイッチをオンにします。 3. 船内電源のスイッチをオンにします。 保守 ・ 電源スイッチをオンにして、LED が点灯しない場合は、お買い上げの販売店・ 代理店、最寄りの当社支店・営業所にお問い合わせください。 ・ ブレーカが切れた場合は、原因を調査・対応してからブレーカをリセットし てください。 ・ 上記の対応後に、ブレーカが再び切れた場合は、お買い上げの販売店・代理 店、最寄りの当社支店・営業所にお問い合わせください。...
  • Page 18 注 1)電流バランスが崩れるのを防ぐため、本機を 2 台で使用する時は下図の 通り接続機器と本機のメイン、およびサブの間の出力ケーブルの長さを揃 え、ケーブルの抵抗値の差が 3mΩ 以下であることを確認してください。 注 2)バッテリーから電源をバックアップする際は、信号ケーブルの接続は 不要です。 4. 端子台カバーを本機に取 り 付け、 手順 1 で取 り 外 し たネジ を締め付けます。 注)端子台カバーは端子部の防水用途も兼ねているため、必ず取り付けてくだ さい。 4. 基本操作 本機を使用するときは、電源スイッチをオンにします(下図参照) 。 電源スイッチをオンにすると、本機の LED が以下の通り点灯します。 ・ 入力電源として、AC が選択されている場合:緑 ・ 入力電源として、バッテリーが選択されている場合 : 白 ・ 入力がない場合 : 消灯...
  • Page 19 本機を 2 台で使用する場合の結線は、以下の手順で行います。 1. 4 ページの手順 1 を参照して、端子台カバーのネジ 2 本を緩め、端子台カ バーを取り外します。 2. 5 ページの手順 2 を参照して、端子台からバインドセムスネジを緩めて取り 外し、以下のケーブルの結線を行います(下図、および相互結線図参照) 。 ・ TPYC-1.5(AC 入力) ・ DPYC-2.5(DC 入力) ・ TTYCSLA-1(通信、カレントシェア)...
  • Page 20 DPYC‐2.5 の端末処理 注 1)フェライトコアは、本体に近い位置で取り付けてください。 注 2)DC 出力の場合は、フェライトコアに芯線を巻く必要はありません。 15mm 15mm TTYCSLA-1 の端末処理 注)フェライトコアは、本体に近い位置で取り付けてください。...
  • Page 21 ・ 圧着端子(下図参照) :FV2-P4K(電源ケーブル用) 、 FV1.25-M3(LF) RED K(信号ケーブル用) TPYC‐1.5 の端末処理 注)フェライトコアは、本体に近い位置で取り付けてください。...
  • Page 22 2. 端子台のバインドセムスネジを緩めて取り外し、以下のケーブルを接続しま す(下図参照) 。 ・ TPYC-1.5(船内電源からのケーブル) ・ DPYC-1.5(バックアップ用バッテリーからのケーブル) 3. 端子台カバーを本機に取り付け、手順 1 で取り外したネジを締め付けます。 注)端子台カバーは端子部の防水用途も兼ねているため、必ず取り付けてくだ さい。 3. 2 台で使用する場合の結線 端末処理 端末処理は、下記の JIS ケーブルまたは同等のケーブル(現地手配)と圧着端子 (現地手配)を使用して次ページの通り行います。 ・ 電源ケーブル:TPYC-1.5、DPYC-2.5 ・ 信号ケーブル:TTYCSLA-1...
  • Page 23 TPYC-1.5 の端末処理 15mm 15mm DPYC-1.5 の端末処理 15mm 15mm 本機を 1 台で使用する場合の結線は、以下の手順で行います。 1. 端子台カバーのネジ 2 本を緩め、端子台カバーを押し上げて取り外します。...
  • Page 24 3. ネジをしっかりと締め、本機を固定します。 2. 1 台で使用する場合の結線 端末処理について 端末処理は、下記の JIS ケーブルまたは同等のケーブル(現地手配)と圧着端子 (現地手配)を使用して次ページの通り行います。 ・ 電源ケーブル:TPYC-1.5、DPYC-1.5 ・ 圧着端子(下図参照) :FV2-P4K...
  • Page 25 システム構成 1. 機器の装備 本機は、卓上装備(据置装備)および壁掛装備が可能です。装備を行う際は巻末の 外寸図もあわせて参照してください。 装備を行う際は、次の点に注意してください。 ・ 本機の防塵・防水性能は 据え置き(IP22) 、壁掛け (IP20) です。 水しぶきや雨水が、直接当たらない場所を選んでください。 ・ 機器の放熱のため、2 台で使用する際は機器を直接重ねて装備しないでくだ さい。 ・ 本機の装備と結線は、必ず配電盤の電源スイッチを切った状態で行ってくだ さい。 ・ 装備時は、外寸図を参照して必要なサービス空間を確保してください。確保 されていない場合、メンテナンスを行うことができなくなります。 装備の手順は、以下の通りです。 1. 外寸図を参照し、タッピンネジ(4×16、現地手配)を取り付ける下穴(4ヵ 所)を固定位置に開けます。 2. 本機を固定位置に置き、ネジ穴を合わせます。...
  • Page 26 ・ 整流器:RU-1746-B2、RU-3423、および RU-3424 重要なお知ら せ PR-241 の仕様が、 DC バ イ パ ス非対応か ら DC バ イ パ ス対応に変わ り ま し た。 各仕様の区別は、 白点の有無で確認 し て く だ さ い (下図参照)。 仕様変更前 と 同様に、 最大 2 台ま で並列接続で使用 す る こ と がで き ます。 ただ し 、 DC パ イ パ ス対応機 と 非対応機を並列接続で使用す る こ と はで き ま...
  • Page 27 安全にお使いいただくために [ 必ずお守りください ] お使いになる人や他の人への危害、財産への損害を未然に防止するため、以下のことを必ずお 守りください。表示内容を無視して誤った使い方をしたときに生じる危害や損害の程度を、本 書では次の表示で区分し、説明していますので十分に気をつけてください。 WARNING To avoid electrical shock, do not remove cover. No user-serviceable parts inside.
  • Page 28 AC/DC 電源ユニット PR-241 装備ガイド 型式 安全にお使いいただくために ................... i 概要 ..........................1 構成表 ..........................1 システム構成........................2 1. 機器の装備 ........................2 2. 1 台で使用する場合の結線................... 3 3. 2 台で使用する場合の結線................... 5 4. 基本操作 ........................9 仕様 ..........................SP-1 外寸図 .......................... D-1 相互結線図 ........................S-1 www.furuno.com...

Table of Contents