Technical specifications

Note
Device specifications
Siemens makes every attempt to ensure the accuracy of these specifications but reserves the
right to change them at any time.
For a complete listing, including Approvals, see the full operating instructions.
5.1

Specifications

Specification
Process Application
Application
Max. range
Min. range
Vessel Pressure
Operation
Beam Angle
Frequency
Temperature
Sensor
Supply Source
Environmental
Location
Max. altitude
Max. tempera‐
ture
Min. tempera‐
ture
Pollution de‐
gree
Construction
Transducers
Compact Operating Instructions, 09/2021, A5E43390688-AC
XRS-5/5C
ST-H
Liquids
1)
8 m (26 ft)
10 m (33 ft)
0.3 m (1 ft)
Vented to atmosphere
10°
12°
44 kHz
Internal
Transducer shall only be supplied by a Siemens certified controller
Indoor/outdoor
2000 m
65 °C (149 °F)
ATEX and
UKEX:
60 °C (140 °F)
-20 °C (-4 °F)
-20 °C (-5 °F)
4
XPS-10
XPS-15/15F
Liquids and Solids
15 m (50 ft)
Standard:
0.3 m (1 ft)
XPS-15F:
0.45 m (1.5 ft)
95 °C (203 °F)
-40 °C (-40 °F)
Standard:
-40 °C (-40 °F)
XPS-15F:
-20 °C (-4 °F)
5
XPS-30
30 m (100 ft)
0.6 m (2 ft)
30 kHz
-40 °C (-40 °F)
33