Installing/mounting
3.4 Mounting
Flange, gasket, and hardware supplied by customer.
Note
Tighten the flange bolts evenly in order to ensure a good seal between the mating flanges.
Potential performance degradation
Overtightening can cause performance degradation.
• Do not tighten with excessive force.
22
Nipple welded to blind flange
Optional hazardous seal
CAUTION
Optional hazardous seal
Factory flanged transducer
Bolt
Gasket (customer supplied)
Customer flange, flat face only
Nut
Compact Operating Instructions, 09/2021, A5E43390688-AC