3. INSTALLATION (continued)
3E - INSTALLING PARTS SHIPPED LOOSE: CONDENSATE CATCH PAN
Some units may come with the condensate catch pan shipped loose. Place the catch pan over the pan support brackets.
Slide the catch pan all the way to the back of the table under the drain outlets. NOTE: Drain should be located above the
condensate evaporator opening (See Fig. 4).
4. REFRIGERATION LINES (REMOTE UNITS)
REFRIGERATION LINES ARE SHIPPED
UNDER PRESSURE. USE CAUTION WHEN OPENING
LINES.
On remote units, refrigeration lines for suction and supply
are located on the back of the unit near the bottom (See Fig.
4). The suction line is marked "Suction" and is 3/8" copper
tubing. The supply line is 1/4" copper. See "Electrical Con-
nections" section for wiring instructions.
If no holding charge is evident upon opening lines, contact
Traulsen Service and Parts Department at (800) 825-8220
immediately.
Cut refrigeration tubing with tube cutter (not a hacksaw) and
deburr end of tube. Degrease tubing prior to field connec-
tion. Use Sil-Fos® 5% for refrigerant line brazing. 50/50 or
cold solder is not acceptable for use.
For system charge, follow remote refrigeration system man-
ufacturer's instructions.
Fig. 4

5. ELECTRICAL CONNECTIONS

Refer to the wiring diagram shipped with the unit located in-
side the compressor compartment or on the back of the unit.
CORD CONNECTED UNITS (Self-Contained models)
Plug the unit into a properly sized outlet. See data plate lo-
cated inside storage cabinet for circuit sizing.
THREE-PRONGED GROUNDING PLUG. THE OUTLET
TO WHICH THIS PLUG IS CONNECTED MUST BE PROP-
ERLY GROUNDED. IF THE RECEPTACLE IS NOT THE
PROPER GROUNDING TYPE, CONTACT AN ELECTRI-
CIAN.
PERMANENTLY WIRED UNITS (Remote models)
A junction box located on back of the machine near bottom is
provided for electrical field connections. See wiring diagram
shipped with unit on the back of the unit for electrical ratings.
WARNING: THIS MACHINE IS PROVIDED WITH A
TRP SERIES
Page 5