10. TIPS

HOW TO ENSURE LONG LIFE AND GREAT PERFORMANCE IN TRAULSEN PREP TABLES.
1. Make sure time clock is set correctly. Pay CLOSE attention to the AM/PM sides of the dial. This makes a huge difference
in performance. Please refer to detailed instruction sheet.
2. Make sure that temperature controllers for rail and base are set correctly. Please refer to detailed instruction sheets.
3. Make certain air intake filters below condensing unit are cleaned or replaced regularly. Depending on the kitchen envi-
ronment, this may be monthly or quarterly procedure.
4. Keep drain strainers clean and in place. Clogged drains mean water will accumulate and freeze, causing poor operation
/cooling in rail.
5. ALL pan openings in the cold rail must be covered with proper sized hotel pans AT ALL TIMES to ensure proper operation;
this is due to the airflow in the rail.
6. Please make sure that compressor area covers are in place at ALL times.
7. Do not store anything in the compressor area.
8. Keep rails clean of debris, and wipe up spills immediately. Keeping the rails clean will help avoid problems in item 9
below.
9. NEVER dump water into the rail when cleaning. This can overflow into the fan, causing failure and the resulting service
call.
10. Do not use sharp utensils to clean the gaskets. Wiping them down daily ensures easy cleaning.
11. Make certain that casters get wiped down regularly, if they get clogged with grease, they will eventually "flat spot" and
fail.
12. Units 36" (914.4mm) and shorter have a rear mount compressor and should not be pushed against a wall and should
have a minimum clearance on both sides of at least 3" (76.2mm). They breathe from the rear and need all the air they can
get!
13. Do not place trash receptacles or any other "solid" object in front of compressor areas, again the air flow is needed for
proper breathing.
14. Be aware of condensate evaporator and plug underneath unit, particularly when mopping or sweeping. Also make sure
plug is fully seated.
15. Evaporator coils in bases should be cleaned every six (6) months. Unplug unit or disconnect power, then access by
removing the four (4) Phillips head screws on the rear access cover and remove cover. Clean with vacuum cleaner or soft
brush.
16. Keep your eyes open for conditions that hinder cooler operation. Items such as shelving with heat lamps above refriger-
ated rail and adjacent cooking equipment that though off heat which could hinder the refrigerators performance.

11. SERVICE

For additional information, contact the Traulsen Parts and Service Department: (800) 825-8220 between 7:30 am – 4:30
pm CST, Monday thru Friday. You may also log onto www.traulsen.com for further information. Traulsen QR Code