8. MAINTENANCE PROCEDURES (continued)
8C - CLEANING: PAN CHILLER
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY BEFORE CLEANING ANY PARTS ON THE UNIT.
DO NOT HOSE DOWN OR POUR WATER OR LIQUID CLEANERS IN THE PAN CHILLER COMPARTMENT AS THIS
COULD CAUSE DAMAGE TO THE PAN CHILLER AND REQUIRE AN AUTHORIZED SERVICE TECHNICIAN TO RE-
PAIR. FAILURE TO FOLLOW THIS INSTRUCTION WILL VOID WARRANTY.
The drain is provided for condensate runoff during the defrost cycle. Use a soft cloth or sponge to clean the pan chiller. Al-
ways exercise caution to avoid getting the fan assembly wet.
There are two drains in the pan chiller. Both drains must be cleared/cleaned regularly for proper operation. Drains should be
cleaned a minimum of once a month.
The top drain in the pan chiller compartment is typically located at the right end above the louvered compressor compart-
ment. A removable screen has been provided to prevent the drain from clogging (See Fig.14). Clear drain of dirt and debris
so that condensate can flow freely. This drain is provided for condensate run off from defrosting of chiller plates.
A second drain located below the fan assembly in the pan chiller must also be properly maintained and functional (See Fig.
15). To access this drain, remove the fan shroud and fan housing assembly. (A 7/16" hex socket is required to remove the
fan assembly cap screws). Clear drain of dirt and debris so that condensate can flow freely. This drain is provided for con-
densate run off from defrosts cycle.
Fig. 14
8D - CLEANING: CONDENSING UNIT:
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY BEFORE CLEANING ANY PARTS ON THE UNIT.
Unit performance and operating efficiency are significantly affected by the amount of air passing through the condenser.
Condenser fins that are clogged with dirt and debris greatly reduce required airflow.
Failure to keep the coil fins and the air filter clean may cause premature compressor failure, which will not be covered by
warranty. (On models that contain filters, operating unit without filter will void warranty).
TRP SERIES
Page 10
DRAIN
Fig. 15
PAN
CHILLER
FAN
MOUNTING
HOLES
DRAIN