Section E; Operation; Before Ignition - Toyostove Laser 60AT Installation And Operation Instructions Manual

Laser clean heating system/vented heater
Table of Contents

Advertisement

SECTION E:

OPERATION

1.
Open the Valve(s)
Open the valve(s) of the external fuel tank.
2.
Start the Fuel flow
If using heater for the first time, or after heater has been out of fuel, press
the red reset button once for a period of one second in order to send fuel
to the fuel sump.
Note:
Make sure there is no fuel leakage from the fuel line or joints.
Also make sure fuel tank is not too high. See installation instructions.
3.
Plug in the Heater
Plug heater into a 120V AC electrical outlet.
Note:
Do not connect to an outlet shared with other appliances.
4.
4.
Set Clock
Important: Clock on the heater always
must be set to current time.
A. Position timer selector to "CLOCK SET".
B. Press "HOUR" and "MINUTE" button
of TIMER/CLOCK SET to correct time.
Important: Check for the AM or PM
indicators, to insure the
correct time.
Note:
"HOUR" or "MINUTE" button will
change the time every one (1)
unit.
Holding
continuously will cause the time
to change rapidly.
Note:
In the event of a power failure over ten (10) seconds, all clock and timer settings are cancelled.
Digital indicator will flash "PM 12:00" when heater is off, or "AUTO" lamp will flash when
heater is on and in automatic operation, after is power is restored. However, no indications
when heater is in manual operation. At this point, you need to reset all time and set-back
functions.
C. Position timer selector to "CLOCK/TEMP (NORMAL POSITION)" after clock setting is completed.
Current time will be shown on digital indicator.
Operation of Laser Heater can be controlled manually by the user - "MANUAL" operation (NORMAL mode
only) or run automatically by the programming - "AUTOMATIC" operation (NORMAL mode and SET-BACK
mode).
MANUAL OPERATION
"MANUAL" operation means that the set-back will not be in use but in "NORMAL" mode.
Operation of the heater is under the direct control of the user ("AUTO" switch is off). Heat output will,
however, be automatically adjusted in accordance with the room temperature registered by the
temperature sensor.

BEFORE IGNITION

the
button
OPERATION
SET
ROOM
8. ON/OFF lamp
TEMP
AM PM
BURNER
AUTO
BURNING MODE
LO MED HIGH
TIME/CLOCK SET
4. Timer & clock set
HOUR
HOUR
10. Normal temper-
TEMP SELECT
NORMAL
SET - BACK
ature lamp
90ºF
32ºC
70
21
50
10
1. ON/OFF switch
BURNER
AUTO
(NORMAL POSITION)
CLOCK / TEMP
END SET-BACK
START
5. Timer selector
CLOCK SET
SET-BACK
Reset Button
6. Digital Indicator
9. Auto lamp
7. Burning mode lamp
11. Set-back temper-
ature lamp
3. Temperature
selectors
2. Auto switch
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents