SECTION A:

SPECIFICATIONS

Model:
Heater Efficiency:
Heat Rating:
Fuel Consumption:
Fuel System:
Fuel Type:
Dimensions (W
(Includes drip tray)
Weight:
Vent Pipe Hole:
Maximum Length of Vent Pipe System:
Electrical Rating:
Typical Room Size (3):
(1)
Heat and vaporized water are produced by the combustion process of this kerosene heater. This rating
does not take into account heat loss due to condensation of water vapor.
(2)
External tank to be purchased from local suppliers.
(3)
0˚ F Heat Load
20˚ F Heat Load = 20 BTU/ft
Room size for which this heater is suitable will vary depending on outside temperature, house
insulation, window size, and other factors.
2
´
´
H
D):
= 24 BTU/ft
/hr
2
/hr
2
Laser 60AT
90% (1)
High - 30,000 BTU/h (8,800 Watts)
Med - 21,000 BTU/h (6,160 Watts)
Low - 12,000 BTU/h (3,520 Watts)
High - 0.230 gal/h (0.870 L/h)
Med - 0.161 gal/h (0.609 L/h)
Low - 0.095 gal/h (0.360 L/h)
External tank (2)
ASTM D3699 1-K Kerosene or ASTM D396 No.1 Fuel Oil
´
´
30"
24"
19"
´
´
(76.0
60.8
48.3 cm)
77 lbs. (35 kg) Empty
2-3/4" ~ 3" diameter
(7.0 - 7.5 cm)
10 ft. (3 m), 3 bends or less
120 Volts AC, 60 Hz
Preheat - 280W
Burning - 76W
1250 square feet (0˚F)
1500 square feet (20˚F)