Heater Efficiency:
Heat Rating:
Fuel Consumption:
Fuel system:
Fuel Type:
Dimensions (W × H × D):
Weight:
Vent Pipe Hole:
Maximum Length of Vent Pipe System:
Electrical Rating:
Typical Room Size (3):
(1) Heat and vaporized water are produced by the combustion process of this kerosene heater. This rating
does not take into account heat loss due to condensation of water vapor.
(2) External tank to be purchased from local suppliers.
(3) 0° F Heat Load
= 24 BTU/ft
20° F Heat Load = 20 BTU/ft
Room size for which this heater is suitable will vary depending on outside temperature, house insula-
tion, window size, and other factors.
Laser 30
90% (1)
High - 14,800 BTU/h
Med - 10,000 BTU/h
Low - 5,200 BTU/h
High - 0.108 gal/h
Med - 0.076 gal/h
Low - 0.040 gal/h
External tank (2)
ASTM D3699 1-K Kerosene or ASTM D396 No.1 Fuel Oil
16-15/16" × 21-3/4" × 13-9/16"
31 lbs. Empty
2-3/4" ~ 3" diameter
10 ft., 3 bends or less
120 Volts AC, 60 Hz
Preheat - 260W
Burning - 26W
600 square feet (0°F)
720 square feet (20°F)