3 ) Using The Unit With External Sync Signal; (3. 1) H (Horizontal) Phase Adjustment; 4 ) Changing Hd/Vd Input/Output; Synchro. Scan Operation - Toshiba IK-TF5C Instruction Manual

3 ccd camera
Table of Contents

Advertisement

( 3 ) Using the unit with external sync signal

When adjusting H (horizontal) phase refer to the item "7.2 (5) (5.1) Adjusting horizontal phase".

(3. 1) H (horizontal) phase adjustment

Observe the external sync signal and the LVAL signal output
waveform of the unit with a dual trace oscilloscope, and ad-
just H phase so that the H phases match.

7. 4 Synchro. Scan Operation

The shutter speed can be set by the horizontal scanning period (1H) or by the frame.

( 1 ) Setting by 1H

1H/525H to 524H/525H (1H/262H to 261H/262H at 120fps and E.120fps of Partial Scanning, 1H/175H to
174H/175H at 180fps and E.180fps of Partial Scanning) stands for the setting by the 1H and the shutter speed
can be set by the 1H (31.8 ms).

( 2 ) Setting by the frame

2FRM to 512FRM stand for the setting (long period exposure) by the frame.
The video signal stored during the frame period set is output as 1 frame video image at a frame interval
specified.
(Internal VD)
RGB data
(video interval image)
FVAL
LVAL,
DAVL
n
(4FRM setting)
Match
the phase.
n+1
External
Sync. signal
LVAL signal
output
23

Advertisement

Table of Contents
loading