(1. 3) Changing Each Setting In; E.trg Mode; (1. 3. 1) Changing Each Setting In 1P Snr Mode - Toshiba IK-TF5C Instruction Manual

3 ccd camera
Table of Contents

Advertisement

(1. 3) Changing each setting in E.TRG mode
The E.TRG has five modes; 1P SNR, 1P SR, PW SNR, PW SR, RR.
First set the "→" to MODE and select E. TRG, then set the "→" to E.TRG and select the desired E.TRG mode.

(1. 3. 1) Changing each setting in 1P SNR mode

Move up down
By pushing
MENU UP, DOWN
-- SHUTTER --
MODE
E.TRG
TRG.P
EXP.
PART
<MODE = E.TRG E.TRG = 1P SNR>
(a) Changing the polarity of inputting trigger pulse setting
1 Set the "→" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
2 Select either
(b) Changing 1P SNR exposure time setting
1 Set the "→" to EXP. by pushing [MENU UP], [MENU DOWN] buttons.
2 Set the exposure time by pushing [DATA UP], [DATA DOWN] buttons.
Note:
The longer the storage time with extended exposures, the more visible certain characteristics of CCD
cameras become: fixed pattern noise, white pixels, etc.
(c) Changing the partial scanning setting
1 Set the "→" to PART by pushing [MENU UP], [MENU DOWN] buttons.
2 Select either OFF/120fps/180fps/E.120fps/E.180fps by pushing [DATA UP], [DATA DOWN] buttons.
14
Set by pushing
DATA UP, DOWN
E.TRG
1P SNR
16ms
OFF
,
by pushing [DATA UP], [DATA DOWN] buttons.
• Sutter mode MANU, SS, E.TRG

• E.TRG mode

1P SNR, 1P SR, PW SNR, PW SR, RR
• Input trigger pulse setting at 1P SNR and 1P SR
Input trigger pulse : positive polarity
Input trigger pulse : negative polarity
• Exposure time setting at 1P SNR and 1P SR
0.01 ms
0.02 ms
0.01 ms
0.02 ms
step
• Partial scanning switch
OFF/120fps/180fps/E.120fps/E.180fps
0.4 ms
1 ms
0.1 ms
1 ms
step
step
step
16 ms

Advertisement

Table of Contents
loading

Table of Contents