ELECTRICAL CONNECTION
REQUIREMENTS
This appliance must be installed and grounded on a branch
circuit by a qualified technician in accordance with the
National Electrical code ANSI/NFPA NO. 70 - latest edition.
Ail wiring should conform to Local and NEC. This range
requires a single-phase, 3 wire, A.C 120/208V or 120/240V 60Hz
electrical system. Use only a 3-conductor or a 4-conductor
UL-listed range cord with closed-loop terminals, open-end
spade lugs with upturned ends or similar termination. DO
NOT install the power cord without a strain relief.
A range cord rated at 40 amps with 120/240 minimum volt
range is required. If a50 amp range cord is used, it should
be marked for use with 1%" diameter connection openings.
This appliance may be connected by means of conduit or
power cord. If conduit is being used, go to page 7 for 3 wire
conduit connections or page 8 for 4 wire conduit connections.
(
4 WARNING
)
* New branch-circuit installations (1996 NEC)
for mobile homes, recreational vehicles, and
installations where local codes do not allow
grounding through the neutral wire require a
4-conductor UL listed range cord or 4 wire
conduit connection.
* Power supply cord and plug should not be
modified. If it will not fit the outlet, have a proper
outlet Installed by a qualified electrician.
* Using an extension cord to connect the power is
prohibited. The way to connect the power cord
and plug directly is strongly recommended.
* Electrical ground is required on this appliance.
* You should make sure that the power cord is
not pinched by the range or heavy objects.
\° Failure to do so can result in serious burns or electrical shock. }
Specified power-supply-cord kit rating
Diameter (inches) of Range
Range rating, watts
chron
canbe
connection Opening
120/240 volts | 120/208 volts | nord kit amperes
Power cord
Conduit
3-wire
3-wire
'
8,750 - 16,500 | 7,801 - 12,500
40 or 50A
Pie"
Ye"
16,501 - 22,500}
12,501 - 18,500
50
fa"
Pe"
3, 4- Wire electrical wall Receptacle
G
4 Wire receptacle (14-50R)
ci
.
(W743 Wire receptacle (10-50R)
FIGURE 3
ELECTRICAL CONNECTIONS
[4] CONNECT RANGE CORD
44 WARNING
- You never remove the protection cover
covering the rear of lower oven.
- Failure to do so can result in serious damage to power cord.
The damage causes serious burns and electric shock.
The Rear Access cover must be removed. Loosen the
three screws with a screwdriver. The terminal block
will then be accessible.
Terminal block
Access cover
Protection cover
SN
Cord/Conduit
Rear of lower oven
Connection
plate
FIGURE 4
The Cord/Conduit connection plate is used for the
installation of power cord or conduit. For power cord,
install it with the connection plate as INSTALLED. For
conduit, remove the connection plate located below the
rear of the drawer body and use the conduit hole (1'/.")
instead of power cord hole (1°/."). (Refer to Figure 5 and 6.)
f
'
————
11g"
=
=
(2.8m)
(Cord)
—]
SS,
rene
11/8"
_
(Conduit)
13/8"
8
(3.5 cm)
L
Remove the Conduit connection plate
J
FIGURE
5
f~
a
Cord/Conduit
connection
plate
Strain relief
Conduit
Assemble the
strain relief hole
Reinstall the Cord/Conduit connection plate
FIGURE 6