Wiring Diagram - Goodman AVPTC 14 Series Installation & Operating Instructions Manual

Table of Contents

Advertisement

30 Wiring Diagrams
(SEE NOTE 4)
TO
GROUND LUG
HEATER KIT
8
5
4
3
9
7
6
COM
RD
INSTALLING
BL
WH
AUX ALARM
(ALARM)
AUX
~ ~
(SEE NOTE 7)
OUT
BR
AUX
~ ~
IN
RELAY OUT
RELAY OUT
BL
(EAC-OUT)
RELAY IN
RELAY IN
(EAC-IN)
HEATER KIT
OUTPUT
NOTES:
1. PLACE RED WIRE ON 208 V TERMINAL OF TRANSFORMER (TR1)
FOR 208 VAC OPERATION.
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED
WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH THIS UNIT MUST
BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL
HAVING A TEMPERATURE RATING OF AT LEAST 105°C. USE COPPER
CONDUCTORS ONLY.
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C
AND LOCAL CODES.
6. DISCARD CONNECTOR PL1 WHEN INSTALLING OPTIONAL HEAT KIT.
7. REMOVE JUMPER TAB AND PUT AUX ALARM SWITCH WHEN
INSTALLING AUX ALARM SWITCH.
9. USE N.E.C CLASS 2 WIRE.
10. SEE MANUAL FOR PUSH BUTTON OPERATION.
11. SEE MANUAL FOR 7-SEGMENT DISPLAY DIAGNOSTIC CODES AND
MENU CODES
12. SEE MANUAL FOR LED FUNCTIONALITY.
13. R AND C TERMINALS (USED FOR 24VAC OUTDOOR CONTROL
VOLTAGE) ARE OPTIONAL FOR 2 STAGE COMMUNICATING AIR
CONDITIONERS. R AND C TERMINALS ARE NOT TO BE USED FOR 2
STAGE COMMUNICATING HEAT PUMP APPLICATIONS.
FOR COMMUNICATING HEAT PUMPS OR IF ONLY TWO THERMOSTAT
WIRES ARE AVAILABLE, A SEPARATE TRANSFORMER MUST BE
INSTALLED IN THE OUTDOOR UNIT FOR CONTROL BOARD POWER.
1 AND 2 WIRES ARE REQUIRED FOR ALL APPLICATIONS. SEE
INSTALLATION MANUAL FOR FULL SYSTEM WIRING EXAMPLES.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
HIGH VOLTAGE!
D
ISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT
M
ULTIPLE POWER SOURCES MAY BE PRESENT
CAUSE PROPERTY DAMAGE
208/230 VAC
L2 L1
(SEE NOTE 6)
RD BK
PL1
2
1
PL2
BK
RD
208
VAC
230
VAC
TR1
24VAC
(SEE NOTE 1)
THERMOSTAT
AUX ALARM
AUX ALARM
(ALARM)
GR
J19
AUX
AUX
G
C
Y
W
R
IN
OUT
TH1
TR1
J1
DH/Y2
LEGACY INPUT
TB1
TB2
EAC-OUT
F1U
TB6
COM
J11
J14
EAC-IN
TB5
TB7
TH2
TR2
TB3
TB4
J13
PS
PS
PS
FLASH WRITER
F2U
(SEE NOTE 10)
MPU
SEG3
K1R
PB3
K2R
J12
J15
SEG2
PB2
GND
SEG1
PB1
NC
J4
(SEE NOTE 11)
J8
J9
SAT
RAT
(SUPPLY AIR
(RETURN AIR
TEMPERATURE)
TEMPERATURE)
LOW VOLTAGE FIELD
HIGH VOLTAGE FIELD
,
PERSONAL INJURY OR DEATH
ECM MOTOR
DISCONNECT
FAN
MOTOR
RD
BK
GY BL
OUTDOOR UNIT
(SEE NOTE 13)
R
C
R
2
1
J2
CT COMM
J3
W
Y
J5
LED
G
(SEE NOTE 12)
U10
DH/Y2
INDOOR UNIT
PCB
C
INTEGRATED CONTROL:
COLOR CODES:
BL - BLUE
LOW VOLTAGE
RD - RED
YL - YELLOW
HIGH VOLTAGE
OR - ORANGE
BK - BLACK
JUNCTION
GY - GREY
TERMINAL
BR - BROWN
INTERNAL TO
GR - GREEN
RESISTOR
OVERCURRENT
PU - PURPLE
PROT. DEVICE
WH - WHITE
PLUG CONNECTION
EQUIPMENT GND
FIELD GROUND
27
.
. F
AILURE TO DO SO MAY
.
L1
GRND
INDOOR
AIR
CIRCULATOR
BLWR
208/230 VAC
L1
FUSE 3 A
TH2
24 VAC
W1 (1)
HEAT 1 COIL/R1
W2 (2)
HEAT 2 COIL/ R2
CAS (1)
CONDENSATE AUX SWITCH
CAS (2)
TO
MICRO
+VDC (1)
RX (2)
TX (3)
GRND (4)
TR2
COM
INTEGRATED CONTROL MODULE
COMPONENT CODES:
POWER/HEATER
PL1, PL2
CONNECTOR
TL
THERMAL LIMIT
TR
TRANSFORMER
F1U, F2U
FUSE LINK
TRANSFORMER
PL3, PL4
CONNECTOR
L2
GRND
L2
40 VA
TRANSFORMER
INDOOR
AIR
CIRCULATOR
BLWR
GRND
0140A00716-A