E-5
P.C. BOARD TROUBLESHOOTING GUIDE
WARNING
ELECTRIC SHOCK
• Have an electrician install and service
this equipment.
• Turn the input power off at the fuse
box before working on equipment.
• Do not touch electrically hot parts.
---------------------------------------------------------------------
Machine settings for P.C. board troubleshooting.
Disconnect all leads to the wire feeder and jumper ter-
minals #2 and #4 on DC-1000. Output Control at DC-
1000. Mode switch in the CV(I) position.
CONTROL/FAULT PROTECTION P.C.
BOARD
1. LED1 indicates AC input voltage is present at pins
255-256. If not lit, check the voltage across the
secondary winding of the control transformer, T2.
The voltage should be approximately 115 volts. If
not, the problem is in the power supply and not the
P.C. board.
2. LED2 indicates welder output voltage is being sup-
plied to the control circuit. If not lit, check to make
certain lead 222 from pin 2 of the 15-pin control
circuit P.C. board connector is connected to the
power source negative output lead and is not bro-
ken.
3. LED3 indicates power is being applied to fault pro-
tection pilot relay 2CR to turn on the input contac-
tor.
4. LED4 indicates when overcurrent protection circuit
is being activated.
5. LED5 indicates a control signal is being supplied
to the firing circuit. As the output control is varied,
LED5 should change brilliancy from bright at low
output to dim at high output.
FIRING CIRCUIT P.C. BOARD
All nine light emitting diodes must be lit when the
power source is turned on and the wire feed arc start
button is pressed or a jumper is connected between 2
and 4.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
can kill.
IDEALARC® DC-1000
1. Lights 7, 8, and 9 indicate AC power being sup-
plied to the P.C. boards from T1 auxiliary winding.
If a light is not lit, turn the machine off and unplug
P5 from J5 on the firing P.C. board. Turn the
machine on and check the following voltages:
Light That
Was Off
7
8
9
If approximately 75 VAC is present, turn the
machine off, plug P5 back into firing board. Turn
the machine back on and check to see if the light
or lights are on. If the light or lights are not on
replace the firing P.C. board.
If the 75 VAC was not present, then check the
wiring.
2. Lights 1 through 6 indicate gate signals are being
supplied to the main power SCRʼs 1 through 6
respectively. If light 5 on the control circuit and
lights 7 through 9 on the firing circuit are lit and
lights 1 through 6 are not lit, check lead 231
between the firing circuit and the control circuit
that it is not broken and is connected to each
Molex connector. If the lead shows continuity and
lights 1 through 6 are not lit, replace the firing cir-
cuit P.C. board. If any one of the lights 1 through 6
is not lit and lights 7 through 9 are lit, replace the
firing circuit P.C. board.
CAUTION
Check AC Voltage
Voltage Should
Between Pins of
Be Approx.
Plug P5
P5 Pins 2 & 4
75 VAC
(Wires 203, 204)
P5 Pins 7 & 3
75 VAC
(Wires 205, 206)
P5 Pins 9 & 8
75 VAC
(Wires 207, 208)
E-5