BLOWER DATA
EL195UH100NE60C PERFORMANCE (Less Filter)
External
Bottom Return Air, Side Return Air with Return Air from Both
Static
Sides or Return Air from Bottom and One Side.
Pressure
in. w.g.
High
Med-High
cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts
0.00
2156 722 1922 497 1723 370 1589 215 1420 211 2102 118 1833 489 1688 170 1590 300 1375 209
0.10
2112 738 1851 511 1681 388 1552 326 1380 227 2064 730 1809 504 1658 384 1540 314 1347 224
0.20
2076 748 1808 533 1636 403 1525 334 1340 244 2038 749 1789 514 1623 402 1507 331 1325 242
0.30
2035 768 1782 542 1604 425 1488 349 1290 259 2011 760 1761 531 1594 413 1472 348 1266 246
0.40
2009 772 1749 558 1572 433 1441 362 1248 266 1968 770 1726 549 1561 431 1435 355 1247 264
0.50
1942 776 1715 580 1533 452 1424 374 1213 281 1920 776 1685 560 1527 443 1394 374 1199 278
0.60
1881 746 1681 584 1512 468 1357 382 1157 293 1849 741 1660 578 1489 455 1356 379 1154 286
0.70
1790 715 1634 599 1459 474 1319 401 1136 306 1777 723 1622 593 1439 473 1317 395 1124 301
0.80
1702 679 1582 613 1432 491 1300 418 1084 312 1682 681 1588 602 1407 488 1288 408 1067 308
EL195UH Model
Number
040NE36B
060NE36B
080NE60C
100NE60C
Model Number
All Models
Factory Setting
Air Volume / Watts at Different Blower Speeds
Medium
Med-Low
Allowable Heating Speeds
Red
Yellow
Factory Setting
Allowed
Allowed
Allowable Circulation Speeds
Red
Yellow
Not Allowed
Single Side Return Air − Air volumes in bold require
Optional Return Air Base and field fabricated transition to
accommodate 20 x 25 x 1 in. air filter in order to maintain
proper air velocity.
Low
High
Med-High
TABLE 14
Blue
Allowed
Factory Setting
TABLE 15
Blue
Not Allowed
Page 54
Medium
Med-Low
Brown
Black
Not Allowed
Allowed
Not Allowed
Not Allowed
Brown
Black
Not Allowed
Not Allowed
Low