HP 5334B Service Manual page 90

Universal counter
Hide thumbs Also See for 5334B:
Table of Contents

Advertisement

10:
1
PROBE
I,
HP3325A
SYNTHESIZER/
FUNCTION GENERATOR
HP5334B
UNIVERSAL COUNTER
I
I
Figure 5-10. A
f
ferzuator Adjustrlzent Setup
Equipment:
Oscilloscope
.....................................
HP 1715A (or equivalent)
........................
Function Generator
HP 3325A
Procedure:
1. Set the oscilloscope as follows:
A 1 R38
Channel A V/Div.
...........................
0.01V
...........................................
TimeJDiv
0.1 ms
Channel
A
Coupling
.......................
AC
..............................
Main Triggering
INT
...............................
Internal Trigger
A
...............................
Vertical Display
A
..........................
Horizontal Display
MAIN
2.
Set the function generator as follows:
Frequency
.........................................
1 kHz
...........................................
Function
Square Wave
........................................
Amplitude
6 p-p
t
0.3V
3. Set the 5334B as follows:
.....................................
FUNCTION
FREQ A
..............................
SENS (blue key)
ON
............
CH A
&
B SENS Controls
MAX
COM A
.............................................
ON
CHANNEL A AND B
..................
XI0 ATTENUATORS
O N
4.
Connect the function generator output to the 5334B Input A.
HP 5334B
-
Service Manual
5-18

Advertisement

Table of Contents
loading

Table of Contents