Baxi 50 HE Plus Installation & Servicing Instructions Manual page 44

Wall mounted powered flue condensing boilers
Table of Contents

Advertisement

ELECTRICAL SUPPLY
240V at A ?
YES
240V at B ?
YES
PCB fuse OK ?
YES
Replace PCB.
44
© Baxi Heating UK Ltd 2006
Lights
Off Off Off
No Switched Live to
NO
boiler. Check Systems
Controls and System
Wiring.
NO
Check wiring from
terminal block to PCB.
Check for shorts on
NO
pump, fan & gas valve.
Replace if shorted &
replace fuse.
15.0
ON
Fault Finding
A
N
L
B
Fuse
Optional
Pump
Live