Prepare holes at fastener locations as identified below:
For walls, wall studs, or floors composed of solid
wood or metal, drill 1/8" pilot holes.
For walls or floors composed of drywall, sheet-rock
or other soft materials, drill 3/16" holes to a mini-
mum depth of 1-3/4", then tap plastic anchors into
each of the holes using a hammer.
For walls or floors composed of concrete or con-
crete block, drill 3/16" holes to a minimum depth of
1-3/4", then tap concrete anchors into each of the
holes using a hammer.
For walls or floors having ceramic tile covering, drill
3/16" holes through the tile only, then drill into the
material behind the tile as indicated immediately
above.
If the range is moved to a new location, the Anti-Tip
Device must be removed and reinstalled.
Mounting Anti-Tip Bracket
The alternative floor mounted bracket shall be installed as
follows:
1. Place bracket on floor in position shown in Figure 8
(Bracket may be used in either corner of the installation
area).
2. Secure to floor or wall stud.
3. Later, when the unit is installed, the adjustable leg will
slide under the bracket.
Wall Line
Floor
Front Edge of
Right Cabinet
Right
Cabinet
X
typical -
either side
Figure 8: Placement of Anti-Tip Bracket (Top View)
Step 5: Gas Requirements and
Hookup
Verify the type of gas being used at the installation site. As
shipped from the factory, units are configured for use
with only natural gas or propane (LP) gas. Make certain
the range matches the type of gas available at this
location. These ranges are NOT convertible between
different types of gas.
For installation of the appliance at high altitude, please
consult your local gas company for their recommendation
of the correct orifice sizes and any other necessary
adjustments that will provide proper gas combustion at
specified altitudes.
CAUTION
When connecting unit to propane gas, make
certain the propane gas tank is equipped with its
own high pressure regulator in addition to the
pressure regulator supplied with the appliance.
The pressure of the gas supplied to the
appliance regulator must not exceed 14"
(34.9 mb) water column.
Natural Gas Requirements:
Inlet Connection:
Supply Pressure:
Manifold Pressure:
X
from edge of range
X = 4-1/2" (for 30" range)
X = 6-3/4" (for 36" range)
1/2" NPT internal
(Minimum 3/4" dia. flex line.)
6" min. to 14" max. water column.
(14.9 to 34.9 mb)
5" water column (12.5 mb)
English 11