Step 6: Electrical Requirements, Connection & Grounding - Thermador PRG486GDH Installation Manual

Thermador prg486gdh: install guide
Hide thumbs Also See for PRG486GDH:
Table of Contents

Advertisement

Available languages

Available languages

Figure 10: Location of Gas Supply Inlet Connection on 48"
Step 6: Electrical Requirements, Connection & Grounding
Before installing, turn power OFF at the service panel.
service panel to prevent power from being turned ON
accidentally.
MODEL
TYPE
30"
36"
36" with griddle
48" with griddle
For these gas range models, a neutral supply wire
must be provided from the power source (breaker/fuse
panel) because critical range components, including
the surface burner spark reignition modules, require
120 VAC to operate safely and properly.
WARNING
An improper 120 VAC power supply will cause
malfunction, damage to this appliance, and
possibly create a condition of shock hazard.
If the correct power supply circuit is not provided, it is
the responsibility and obligation of the installer and
user to have proper power supply connected. This
must be accomplished in accordance with all
applicable local codes and ordinances by a qualified
electrician. In the absence of local codes and
ordinances, the power supply connection shall be in
accordance with the National Electrical Code.
A
Ranges
Lock
Chart B: Electrical Supply Circuit Requirements
VOLTAGE
120 VAC
120 VAC
120 VAC
120 VAC
CIRCUIT
FREQUENCY
RATING
10 Amps
10 Amps
20 Amps
20 Amps
Observe all governing codes and ordinances when
grounding. In the absence of these codes or
ordinances observe National Electrical Code ANSI/
NFPA No. 70 current issue.
Electric wiring diagrams and schematics have been
placed in the toe kick area of the range for access by a
qualified service technician.
Before you plug in an electrical cord, be sure all
controls are in the OFF position.
For appliances equipped with a cord and plug, do not
cut or remove the ground prong. It must be plugged
into a matching grounding type receptacle to avoid
electrical shock. If there is any doubt as to whether the
wall receptacle is properly grounded, the customer
should have it checked by a qualified electrician.
Installer — show the owner the location of the circuit
breaker or fuse. Mark it for easy reference.
PHASE
60 Hz.
Single
60 Hz.
Single
60 Hz.
Single
60 Hz.
Single
English 13